MétaCan
Menu
Back to cohort
Record W2021874121 · doi:10.1111/aos.12479

Grader learning effect and reproducibility of Doppler Spectral‐Domain Optical Coherence Tomography derived retinal blood flow measurements

2014· article· en· W2021874121 on OpenAlexaff
Kalpana Rose, Monica Jong, Firdaus Yusof, Faryan Tayyari, Ou Tan, David Huang, Srinivas R. Sadda, John G. Flanagan, Christopher Hudson

Bibliographic record

VenueActa Ophthalmologica · 2014
Typearticle
Languageen
FieldEngineering
TopicOptical Coherence Tomography Applications
Canadian institutionsUniversity of TorontoUniversity of Waterloo
Fundersnot available
KeywordsRepeatabilityReproducibilityOptical coherence tomographyMedicineRetinalOphthalmologySession (web analytics)Grading (engineering)Nuclear medicineBiomedical engineeringComputer scienceMathematicsStatistics

Abstract

fetched live from OpenAlex

PURPOSE: To investigate grader learning effect and to quantify intergrader reproducibility of Doppler Spectral-Domain Optical Coherence Tomography (SD-OCT) derived retinal blood flow measurements. METHODS: Fifteen healthy young subjects (mean age 28.44; SD 3 years) underwent Doppler SD-OCT scans of one eye using the circumpapillary double circular scan protocol of the Optovue RTVue by one of two experienced operators. One trained (i.e. having undergone certification) and one novice (i.e. preliminary training comprising five standard practice data sets) individual then graded a standardized set of scans, consisting of 15 data sets (session 1) using custom Doppler Optical Coherence Tomography of Retinal Circulation (DOCTORC) software. One week later (session 2), the novice grader underwent further training by grading an additional 15 practice data sets and then both graders subsequently regraded the original 15 data sets. RESULTS: Measurements achieved by a novice grader during session 1 showed a trend to be higher in terms of total retinal venous blood flow (TRBF) and also to be significantly (p = 0.03) higher for venous area, compared with a trained grader. Session 2 results were not significantly different for either grader. The mean TRBF for session 2 for the trained and novice grader was 45.29 ± 9.28 μl/min and 44.39 ± 7.36 μl/min, respectively. The coefficient of repeatability (COR) of session 2 TRBF values between the trained and novice grader was 8.09 μl/min. CONCLUSIONS: There is a grader learning effect which impacts the venous area measurements. Reproducible and repeatable retinal blood flow measurements were achieved among trained graders using DOCTORC software.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Direct model labels (unvalidated)

Per-model category and study-design labels from the labeling rounds. They are machine output, unvalidated, and the disagreement between models ships as data. No study design here is MEDLINE-validated yet.

Model armCategoriesStudy designConfidence
gemmano category
Domain: not available · Genre: Empirical
About the Canadian research system: no · About a Canadian topic: no
Observationallow
gptno category
Domain: not available · Genre: Empirical
About the Canadian research system: no · About a Canadian topic: no
Observationalhigh
models agreeAgreement compares identical category sets and study designs across arms.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.379
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.250
Teacher spread0.226 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Labeled directly by 2 models reading the full record.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueActa OphthalmologicaSame topicOptical Coherence Tomography ApplicationsFrench-language works237,207