MétaCan
Menu
Back to cohort
Record W2021934955 · doi:10.1310/hpj4904-355

Hazardous Drug Residue on Exterior Vial Surfaces: Evaluation of a Commercial Manufacturing Process

2014· article· en· W2021934955 on OpenAlexaff
Luci A. Power, P.J.M. Sessink, Kathy Gesy, Flay Charbonneau

Bibliographic record

VenueHospital Pharmacy · 2014
Typearticle
Languageen
FieldHealth Professions
TopicSafe Handling of Antineoplastic Drugs
Canadian institutionsSunnybrook Health Science CentreSaskatchewan Cancer Agency
Fundersnot available
KeywordsVialCisplatinDrug packagingContaminationMedicineSyringeResidue (chemistry)ChromatographySurgeryChemistryOrganic chemistryChemotherapy

Abstract

fetched live from OpenAlex

PURPOSE: Hazardous drug residue on the exterior surface of drug vials poses a potential risk for exposure of health care workers involved in handling these products. The purpose of this article is to heighten the awareness of this serious issue and to evaluate a commercial manufacturing process for removing and containing hazardous drug (HD) residue on exterior vial surfaces. Additionally, findings from this study are interpreted, incorporated into the current body of evidence, and discussed by experts in this field. METHODS: This study includes separate evaluations for the presence or absence of surface drug contamination on the vials of 3 HD products: 5-fluorouracil, cisplatin, and methotrexate. The drug products were packaged in vials using a patented prewashing/decontamination method, application of a polyvinylchloride (PVC) base, and use of clear glass vials. An additional step of encasing the vial in a shrink-wrapped sheath was used for 5-fluorouracil and cisplatin. RESULTS: Of all 5-fluorouracil (110 vials), methotrexate (60 vials), and cisplatin (60 vials) tested, only 2 had detectable amounts of surface residue. One 5-fluorouracil vial was found to have approximately 4 mg of 5-fluorouracil on the surface of the vial. The second contaminated vial was cisplatin, which was discovered to have 131 ng of platinum, equal to 200 ng of cisplatin or 0.2 μL of cisplatin solution, on the vial sheath. CONCLUSION: Using validated extraction and analytic methods, all but 2 of the 230 tested vials were found to be free of surface drug contamination. Pharmacy leaders need to take an active role in promoting the need for clean HD vials. Manufacturers should be required to provide their clients with data derived from externally validated analytic studies, reporting the level of HD contamination on the exterior of their vial products.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.057
GPT teacher head0.437
Teacher spread0.380 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueHospital PharmacySame topicSafe Handling of Antineoplastic DrugsFrench-language works237,207