MétaCan
Menu
Back to cohort
Record W2022671150 · doi:10.1364/oe.17.011719

Femtosecond laser written optofluidic sensor: Bragg grating waveguide evanescent probing of microfluidic channel

2009· article· en· W2022671150 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueOptics Express · 2009
Typearticle
Languageen
FieldEngineering
TopicPhotonic and Optical Devices
Canadian institutionsUniversity of Toronto
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsMaterials scienceFiber Bragg gratingFemtosecondOpticsLaserOptoelectronicsRefractive indexMicrofluidicsGratingWavelengthWaveguideNanotechnology

Abstract

fetched live from OpenAlex

Microfluidic channels and Bragg Grating Waveguides (BGWs) were simultaneously fabricated inside fused silica glass by means of femtosecond laser exposure followed by chemical etching. Evanescent field penetration of the waveguide mode into the parallel microfluidic channel induced Bragg resonant wavelength shifts to enable refractive index characterization of the fluidic medium in the 1 to 1.452 range. Laser exposure was optimized to fabricate devices with optically smooth channel walls and narrow Bragg resonances for high sensing response at 1560 nm wavelength. Reference gratings were also employed in the optical circuit for temperature and strain compensation. These devices open new directions for optical sensing in three-dimensional optofluidic and reactor microsystems.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.060
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.222
Teacher spread0.211 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it