MétaCan
Menu
Back to cohort
Record W2024384381 · doi:10.1088/0031-9155/52/13/010

Evaluating an optical-flow-based registration algorithm for contrast-enhanced magnetic resonance imaging of the breast

2007· article· en· W2024384381 on OpenAlexafffund
Anne L. Martel, Michael S. Froh, Kristy K. Brock, Don B. Plewes, D C Barber

Bibliographic record

VenuePhysics in Medicine and Biology · 2007
Typearticle
Languageen
FieldMedicine
TopicMRI in cancer diagnosis
Canadian institutionsPrincess Margaret Cancer CentreHealth Sciences CentreUniversity of TorontoSunnybrook Health Science Centre
FundersCanadian Institutes of Health ResearchJohnson and Johnson
KeywordsContrast (vision)Computer scienceOptical flowMagnetic resonance imagingComputer visionVoxelIntensity (physics)Dynamic contrastSIGNAL (programming language)Image registrationDisplacement (psychology)Artificial intelligenceAlgorithmBreast MRIBreast cancerMammographyOpticsImage (mathematics)PhysicsRadiologyMedicineCancer

Abstract

fetched live from OpenAlex

Dynamic contrast-enhanced magnetic resonance imaging studies of the breast are frequently degraded by patient motion. In order to correct for this, any registration algorithm must overcome two major challenges: the highly deformable nature of the breast itself and the need to remove changes in signal intensity due to patient motion whilst leaving potentially significant changes in signal intensity due to changes in contrast agent concentration unchanged. In this paper, we evaluate the use of a non-rigid registration method that uses optical flow equations to drive the displacement of a grid of control points. With conventional optical flow techniques it is assumed that changes in image intensity are solely due to motion, making it unsuitable for use with contrast-enhanced studies. The registration algorithm evaluated in this paper overcomes this problem by including an additional term to account for changes in image intensity. Studies simulating physiologically plausible deformations of the breast together with realistic changes in contrast-enhancement derived from patient studies demonstrate that the algorithm is capable of registering images to sub-voxel accuracy within minutes. This technique has now been successfully incorporated into a breast cancer screening protocol allowing registered images to be provided routinely to the radiologist immediately after the scanning session.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.930
Threshold uncertainty score0.287

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.149
GPT teacher head0.440
Teacher spread0.291 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations45
Published2007
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicMRI in cancer diagnosisFrench-language works237,207