MétaCan
Menu
Back to cohort

Clinical utilization of near‐infrared spectroscopy devices for burn depth assessment

2007· article· en· W2025378119 on OpenAlexaff
Karen Cross, Lorenzo Leonardi, Jeri R. Payette, Manuel Gómez, M Levasseur, Bernhard J. Schattka, Michael G. Sowa, Joel Fish

Bibliographic record

VenueWound Repair and Regeneration · 2007
Typearticle
Languageen
FieldMedicine
TopicOptical Imaging and Spectroscopy Techniques
Canadian institutionsHealth Sciences CentreNational Research Council Institute for BiodiagnosticsSunnybrook Health Science Centre
Fundersnot available
KeywordsMedicineNear-infrared spectroscopyHemoglobinBurn injuryOxygenationDeoxygenated HemoglobinBurn woundOxygen saturationHemodynamicsBiomedical engineeringSurgeryNuclear medicineOxygenAnesthesiaInternal medicineChemistryWound healingOptics

Abstract

fetched live from OpenAlex

The diagnosis of burn depth is based on a visual assessment and can be subjective. Near-infrared (NIR) spectroscopic devices were used preclinically with positive results. The purpose of this study was to test the devices in a clinical setting using easily identifiable burn wounds. Adult patients with acute superficial and full-thickness burns were enrolled. NIR point spectroscopy and imaging devices were used to collect hemodynamic data from the burn site and an adjacent unburned control site. Oxy-hemoglobin and deoxy-hemoglobin concentrations were extracted from spectroscopic data and reported as oxygen saturation and total hemoglobin. Sixteen patients (n=16) were included in the study with equal numbers in both burn wound groups. Point spectroscopy data showed an increase in oxygen saturation (p<0.0095) and total hemoglobin (<0.0001) in comparison with the respective control areas for superficial burn wounds. The opposite was true for full-thickness burns, which showed a decrease in oxygenation (p<0.0001) and total hemoglobin (p<0.0147) in comparison with control areas. NIR imaging technology provides an estimate of hemodynamic parameters and could easily distinguish superficial and full-thickness burn wounds. These results confirm that NIR devices can successfully distinguish superficial and full-thickness burn injuries.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.045
GPT teacher head0.420
Teacher spread0.375 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations73
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueWound Repair and RegenerationSame topicOptical Imaging and Spectroscopy TechniquesFrench-language works237,207