MétaCan
Menu
Back to cohort

Comparison of Fingertip to Arterial Blood Samples at Rest and During Exercise

2005· article· en· W2025413737 on OpenAlexaffabout
Gerald S. Zavorsky, Larry C. Lands, Wolfgang Schneider, Franco Carli

Bibliographic record

VenueClinical Journal of Sport Medicine · 2005
Typearticle
Languageen
FieldMedicine
TopicBiomedical and Chemical Research
Canadian institutionsMcGill University Health Centre
Fundersnot available
KeywordsMedicineArterial bloodBlood pressureBlood samplingHemoglobinVO2 maxAnimal scienceCardiologyInternal medicineAnesthesiaHeart rate

Abstract

fetched live from OpenAlex

OBJECTIVE: The purpose was to determine whether arterialized fingertip blood-gas samples are comparable to arterial samples at rest and at exercise. DESIGN: Repeated measures, with subjects serving as their own controls. SETTING: Department of Anesthesia, Montreal General Hospital, Montreal, Quebec, Canada, (January to April 2004). PARTICIPANTS: Fifteen healthy men (age = 25 +/- 4 y; weight = 76.4 +/- 11.4 kg; height = 180.7 +/- 8.0 cm; peak oxygen uptake or VO2peak = 46.0 +/- 9.0 mL . kg . min). MAIN OUTCOME MEASURES: Arterial blood gases, metabolites, electrolytes. RESULTS: Blood sampled simultaneously from the radial artery and warmed fingertip at rest and during 2 levels of exercise (vigorous 181 W or 70% VO2peak; maximal 261 W or 100% VO2peak) on a electronically braked ergometer. Arterial partial pressure of oxygen in blood combining rest and the 2 exercise levels was on average 13.6 +/- 9.0 mm Hg higher than arterialized fingertip samples, with the largest difference occurring at rest (18.8 +/- 6.5 mm Hg; 95% CI = 15.5, 22.1) and the smallest difference occurring at the highest level of exercise (8.3 +/- 9.2 mm Hg; 95% CI = 3.6, 13.0; P < 0.05). The pattern for oxyhemoglobin saturation was the same, showing statistical differences between the sampling sites with the differences reduced at the highest exercise intensity. In contrast, there was no difference in arterial and arterialized partial pressure of carbon dioxide in blood (-1.0 +/- 1.5 mm Hg; 95% CI = -1.4, -0.6), or plasma lactate, glucose, pH, hemoglobin, and electrolytes between both sampling sites at rest or at the 2 exercise levels. CONCLUSION: Arterialized fingertip blood samples at rest and during exercise can predict arterial carbon dioxide pressure, and can predict arterial plasma lactate, glucose, pH, hemoglobin, and electrolytes; but not arterial oxyhemoglobin saturation or arterial oxygen pressure.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.121
GPT teacher head0.462
Teacher spread0.342 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations33
Published2005
Admission routes2
Has abstractyes

Explore more

Same venueClinical Journal of Sport MedicineSame topicBiomedical and Chemical ResearchFrench-language works237,207