MétaCan
Menu
Back to cohort
Record W2026533610 · doi:10.1097/opx.0000000000000340

Comparative Study of Lens Solutions' Ability to Remove Tear Constituents

2014· article· en· W2026533610 on OpenAlexafffund
S.C.H. Cheung, Holly Lorentz, Elizabeth Drolle, Zoya Leonenko, Lyndon Jones

Bibliographic record

VenueOptometry and Vision Science · 2014
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
FundersJohnson and Johnson Vision CareNatural Sciences and Engineering Research Council of CanadaAbbott Medical OpticsUniversity of Waterloo
KeywordsLens (geology)Atomic force microscopySilicone hydrogelChemistryMaterials scienceSurface roughnessAdsorptionBiomedical engineeringContact lensNanotechnologyChromatographyOpticsComposite material

Abstract

fetched live from OpenAlex

PURPOSE: The purpose of this study was to use atomic force microscopy to compare and characterize the cleaning abilities of a hydrogen peroxide-based system (HPS) and a polyhexamethylene biguanide-containing multipurpose solution (MPS) at removing in vitro deposited tear film constituents, as well as to determine deposition patterns on various silicone hydrogel contact lenses. METHODS: Silicone hydrogel materials-balafilcon A (BA), lotrafilcon B (LB), and senofilcon A (SA)-were incubated for 1 week in an artificial tear solution (ATS) containing representative lipids, proteins, and salts from the tear film. Atomic force microscopy was used to resolve each lens before and after being cleaned overnight in HPS or MPS. Atomic force microscopy was used again to resolve HPS/MPS-cleaned lenses, which were reincubated in fresh ATS for 1 week, before and after an overnight clean in their respective cleaning solution. RESULTS: Atomic force microscopy imaging was able to characterize lens deposits with high resolution. Lenses incubated in ATS revealed distinct differences in their deposition pattern across lens materials. The surface of BA contained about 20-nm-high deposits, whereas deposit heights up to 150 nm completely occluded the surface of SA. Lotrafilcon B lenses revealed clusters of deposits up to 90 nm. The use of either lens solution left trace amounts of tear film constituents, although components from the MPS were seen adsorbed onto the surface after cleaning. Surface roughness (Ra) measurements revealed a significant difference between ATS-incubated and HPS/MPS-cleaned SA and LB lenses (p < 0.05). Ra between first incubated and HPS/MPS-cleaned reincubated SA and LB was also significant (p < 0.05). CONCLUSIONS: Unique variations in ATS deposition patterns were seen between lenses with atomic force microscopy. The application of both HPS and MPS removed most visible surface deposits.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.116
Threshold uncertainty score0.229

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.438
Teacher spread0.400 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueOptometry and Vision ScienceSame topicOcular Surface and Contact LensFrench-language works237,207