MétaCan
Menu
Back to cohort
Record W2026807227 · doi:10.1109/tbme.2012.2220356

Improved Localization Accuracy in Magnetic Source Imaging Using a 3-D Laser Scanner

2012· article· en· W2026807227 on OpenAlexafffund
Timothy Bardouille, Santosh Vema Krishnamurthy, Sujoy Ghosh Hajra, Ryan C.N. D’Arcy

Bibliographic record

VenueIEEE Transactions on Biomedical Engineering · 2012
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsDalhousie UniversityIzaak Walton Killam Health CentreNational Research Council Institute for BiodiagnosticsNational Research Council Canada
FundersNational Research Council CanadaIWK Health Centre
KeywordsDigitizationImaging phantomScannerComputer scienceComputer visionArtificial intelligenceLaser scanningLaserMagnetoencephalographyData acquisitionMagnetic resonance imagingOpticsPhysicsMedicine

Abstract

fetched live from OpenAlex

Brain source localization accuracy in magnetoencephalography (MEG) requires accuracy in both digitizing anatomical landmarks and coregistering to anatomical magnetic resonance images (MRI). We compared the source localization accuracy and MEG-MRI coregistration accuracy of two head digitization systems-a laser scanner and the current standard electromagnetic digitization system (Polhemus)-using a calibrated phantom and human data. When compared using the calibrated phantom, surface and source localization accuracy for data acquired with the laser scanner improved over the Polhemus by 141% and 132%, respectively. Laser scan digitization reduced MEG source localization error by 1.38 mm on average. In human participants, a laser scan of the face generated a 1000-fold more points per unit time than the Polhemus head digitization. An automated surface-matching algorithm improved the accuracy of MEG-MRI coregistration over the equivalent manual procedure. Simulations showed that the laser scan coverage could be reduced to an area around the eyes only while maintaining coregistration accuracy, suggesting that acquisition time can be substantially reduced. Our results show that the laser scanner can both reduce setup time and improve localization accuracy, in comparison to the Polhemus digitization system.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.956
Threshold uncertainty score0.578

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.273
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations34
Published2012
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Biomedical EngineeringSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207