MétaCan
Menu
Back to cohort
Record W2026807227 · doi:10.1109/tbme.2012.2220356

Improved Localization Accuracy in Magnetic Source Imaging Using a 3-D Laser Scanner

2012· article· en· W2026807227 on OpenAlexafffund
Timothy Bardouille, Santosh Vema Krishnamurthy, Sujoy Ghosh Hajra, Ryan C.N. D’Arcy

Bibliographic record

VenueIEEE Transactions on Biomedical Engineering · 2012
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsDalhousie UniversityIzaak Walton Killam Health CentreNational Research Council Institute for BiodiagnosticsNational Research Council Canada
FundersNational Research Council CanadaIWK Health Centre
KeywordsDigitizationImaging phantomScannerComputer scienceComputer visionArtificial intelligenceLaser scanningLaserMagnetoencephalographyData acquisitionMagnetic resonance imagingOpticsPhysicsMedicine

Abstract

fetched live from OpenAlex

Brain source localization accuracy in magnetoencephalography (MEG) requires accuracy in both digitizing anatomical landmarks and coregistering to anatomical magnetic resonance images (MRI). We compared the source localization accuracy and MEG-MRI coregistration accuracy of two head digitization systems-a laser scanner and the current standard electromagnetic digitization system (Polhemus)-using a calibrated phantom and human data. When compared using the calibrated phantom, surface and source localization accuracy for data acquired with the laser scanner improved over the Polhemus by 141% and 132%, respectively. Laser scan digitization reduced MEG source localization error by 1.38 mm on average. In human participants, a laser scan of the face generated a 1000-fold more points per unit time than the Polhemus head digitization. An automated surface-matching algorithm improved the accuracy of MEG-MRI coregistration over the equivalent manual procedure. Simulations showed that the laser scan coverage could be reduced to an area around the eyes only while maintaining coregistration accuracy, suggesting that acquisition time can be substantially reduced. Our results show that the laser scanner can both reduce setup time and improve localization accuracy, in comparison to the Polhemus digitization system.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.010
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.273
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations34
Published2012
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Biomedical EngineeringSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207