MétaCan
Menu
Back to cohort
Record W2027074843 · doi:10.1097/qad.0b013e3282ef81ea

Current V3 genotyping algorithms are inadequate for predicting X4 co-receptor usage in clinical isolates

2007· article· en· W2027074843 on OpenAlexafffund
Andrew Low, Winnie Dong, Dennison Chan, Tobias Sing, Ronald Swanstrom, Mark A. Jensen, Satish K. Pillai, Benjamin M. Good, P. Richard Harrigan

Bibliographic record

VenueAIDS · 2007
Typearticle
Languageen
FieldImmunology and Microbiology
TopicHIV Research and Treatment
Canadian institutionsUniversity of British ColumbiaAIDS VancouverSt. Paul's Hospital
FundersCanadian Institutes of Health ResearchHealth ResearchPfizer
KeywordsTropismCo-receptorGenotypingAlgorithmPhenotypeV3 loopComputational biologyReceptorBiologyMedicineInternal medicineGenotypeVirologyMathematicsGeneticsVirusGene

Abstract

fetched live from OpenAlex

OBJECTIVE: Integrating CCR5 antagonists into clinical practice would benefit from accurate assays of co-receptor usage (CCR5 versus CXCR4) with fast turnaround and low cost. DESIGN: Published HIV V3-loop based predictors of co-receptor usage were compared with actual phenotypic tropism results in a large cohort of antiretroviral naive individuals to determine accuracy on clinical samples and identify areas for improvement. METHODS: Aligned HIV envelope V3 loop sequences (n = 977), derived by bulk sequencing were analyzed by six methods: the 11/25 rule; a neural network (NN), two support vector machines, and two subtype-B position specific scoring matrices (PSSM). Co-receptor phenotype results (Trofile Co-receptor Phenotype Assay; Monogram Biosciences) were stratified by CXCR4 relative light unit (RLU) readout and CD4 cell count. RESULTS: Co-receptor phenotype was available for 920 clinical samples with V3 genotypes having fewer than seven amino acid mixtures (n = 769 R5; n = 151 X4-capable). Sensitivity and specificity for predicting X4 capacity were evaluated for the 11/25 rule (30% sensitivity/93% specificity), NN (44%/88%), PSSM(sinsi) (34%/96%), PSSM(x4r5) (24%/97%), SVMgenomiac (22%/90%) and SVMgeno2pheno (50%/89%). Quantitative increases in sensitivity could be obtained by optimizing the cut-off for methods with continuous output (PSSM methods), and/or integrating clinical data (CD4%). Sensitivity was directly proportional to strength of X4 signal in the phenotype assay (P < 0.05). CONCLUSIONS: Current default implementations of co-receptor prediction algorithms are inadequate for predicting HIV X4 co-receptor usage in clinical samples, particularly those X4 phenotypes with low CXCR4 RLU signals. Significant improvements can be made to genotypic predictors, including training on clinical samples, using additional data to improve predictions and optimizing cutoffs and increasing genotype sensitivity.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.025

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.010
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.049
GPT teacher head0.377
Teacher spread0.328 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations141
Published2007
Admission routes2
Has abstractyes

Explore more

Same venueAIDSSame topicHIV Research and TreatmentFrench-language works237,207