A phase I study of oxidized raffinose cross-linked human hemoglobin
Bibliographic record
Abstract
OBJECTIVE: To evaluate the safety of oxidized-raffinose cross-linked human hemoglobin, Hemolink, in normal healthy volunteers. DESIGN: Randomized, placebo-controlled, double-blind study. SETTING: Clinical research facility of a contract research organization. PATIENTS: Forty-two healthy adult male volunteers of which 33 received Hemolink. INTERVENTIONS: Oxidized-raffinose cross-linked and polymerized hemoglobin as a 10% (w/v) solution, in doses of 0.025-0.6 g/kg or an equivalent volume of lactated Ringer's solution, was infused intravenously on day 1, and subjects were monitored for 3 days in the clinical facility with < or =6 wks follow-up. Major organ function was assessed pre- and postinfusion, by hemodynamic, electrocardiographic, pulmonary function, and clinical chemistry measurements. MEASUREMENTS AND MAIN RESULTS: Doses of 1.7-42 g of hemoglobin were administered with no serious adverse events noted. Abdominal pain of moderate to severe intensity was seen in some subjects at doses >0.4 g/kg and was alleviated with smooth muscle relaxants. There was a dose-dependent increase in mean arterial pressure with a plateau of approximately 14% above baseline at 0.1 g/kg. There was a concomitant reduction in heart rate, with no electrocardiographic abnormalities found. Respiratory function was not affected. There was a dose-dependent increase in serum bilirubin with values above the upper limit of normal at doses of > or =0.4 g/kg. Small increases in aspartate aminotransferase and alanine aminotransferase were noted in some patients, whereas alkaline phosphatase and gamma-glutamyltransferase remained in the normal range. Serum amylase concentrations were normal in 31 of 33 patients receiving Hemolink, whereas lipase was within the normal range in 21 of 33 patients. LDH was increased in a dose-dependent fashion. Two patients had increased creatine kinase concentrations, with a normal creatine kinase-MB mass fraction. All hematologic variables were within the normal range. The half-life of the oligomeric (>64 kDa) fraction of Hemolink was 18-20 hrs. CONCLUSION: Oxidized-raffinose cross-linked hemoglobin, Hemolink, at doses < or =0.6 g/kg were well tolerated in healthy volunteers with no evidence of organ dysfunction. Further investigation of its potential use in surgical and trauma settings appears warranted.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.002 | 0.001 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.001 | 0.002 |
| Insufficient payload (model declined to judge) | 0.003 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".