Reference Values for Diagnostic Radiology: Application and Impact

2005· article· en· W2027923935 on OpenAlexaff
Joel E. Gray, Benjamin R. Archer, Priscilla F. Butler, Barry B. Hobbs, Fred A. Mettler, R Pizzutiello, Beth A. Schueler, Keith J. Strauss, Orhan H. Suleiman, Martin J. Yaffe

Bibliographic record

VenueRadiology · 2005
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsUniversity of TorontoWestern University
Fundersnot available
KeywordsMedicineFluoroscopyMedical physicsMedical radiationRadiographyRadiation protectionRadiological weaponMedical physicistPercentileRadiation doseNuclear medicineRadiologyStatistics

Abstract

fetched live from OpenAlex

Reference values (RVs) are recommended by the American Association of Physicists in Medicine for four radiographic projections, computed tomography, fluoroscopy, and dental radiography. RVs are used to compare radiation doses from individual pieces of radiographic equipment with doses from similar equipment assessed in national surveys. RVs recommended by the American Association of Physicists in Medicine have been developed from the Nationwide Evaluation of X-ray Trends survey performed by the state radiation protection agencies with the cooperation and support of the U.S. Food and Drug Administration, the Conference of Radiation Control Program Directors, and the American College of Radiology. The RVs selected by the American Association of Physicists in Medicine represent, approximately, the 80th percentile of the survey distributions. Consequently, equipment exceeding the RVs is using higher radiation doses than is 80% of the equipment in the surveys. Radiation doses for specific projections, with standard phantoms, should be measured annually, as recommended by the American College of Radiology. When the RVs are exceeded, the medical physicist should investigate the cause and determine, in cooperation with the responsible radiologist, whether these doses are justified or the imaging system should be optimized to reduce patient radiation doses. RVs are a useful tool for comparing patient radiation doses at institutions throughout the United States and for providing information about radiographic equipment performance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.051
metaresearch head score (Gemma)0.231
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.051
Threshold uncertainty score0.270

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0510.231
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0070.010
Science and technology studies0.0010.002
Scholarly communication0.0040.003
Open science0.0030.003
Research integrity0.0030.002
Insufficient payload (model declined to judge)0.0180.006

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.335
Teacher spread0.317 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations129
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueRadiologySame topicRadiation Dose and ImagingFrench-language works237,207