Abstract

fetched live from OpenAlex

Abstract Electrochemical Quartz Crystal Microbalance (EQCM) can be used to monitor changes in several material properties, including mass, electrochemical, viscosity, adsorption, and deposition. In this paper, EQCM was evaluated to determine if it can monitor changes to the metal-coating interface well before any visible/physical changes to the coating. Modified cathodic disbondment (CD) experiments were carried out over a period of 14 months on 13 coatings used to protect the external surfaces of oil and gas pipelines. During the experiments, EQCM measurements were recorded by placing the quartz crystal at the coating-steel interface. After the experiments, the CD area was measured and compared with the EQCM measurements. Of the 117 panels of 13 different pipeline coatings tested, for 67 % of coatings EQCM correctly predicted the coating performance. Twenty-five percent of coatings performed better than that predicted from EQCM data. Only for 8 % of coatings EQCM measurements predicted better performance but the coatings disbonded during CD area measurement. Based on these observations it was concluded that microscopic changes to the metal-coating interface could be assessed from oscillation frequency of the EQCM crystal placed at the metal-coating interface. However, in order to obtain useful information, extreme care should be exercised in placing the fragile EQCM crystal at the metal-coating interface.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.747
Threshold uncertainty score0.646

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.230
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueJournal of ASTM InternationalSame topicAcoustic Wave Resonator TechnologiesFrench-language works237,207