MétaCan
Menu
Back to cohort
Record W2028662312 · doi:10.1001/jama.295.16.1907

Complications Associated With Implantable Cardioverter-Defibrillator Replacement in Response to Device Advisories

2006· article· en· W2028662312 on OpenAlexaffabout
Paul A. Gould

Bibliographic record

VenueJAMA · 2006
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsWestern University
Fundersnot available
KeywordsMedicineImplantable cardioverter-defibrillatorComplicationPopulationEmergency medicineSurgeryInternal medicine

Abstract

fetched live from OpenAlex

CONTEXT: Recent implantable cardioverter-defibrillator (ICD) advisories and recalls have caused management dilemmas for physicians, particularly because there are no specific guidelines or data on outcomes from current management strategies. The risk of ICD generator replacement has not been assessed in this population. OBJECTIVE: To determine the complication rate associated with ICD generator replacement for the current ICD advisories. DESIGN AND SETTING: Seventeen ICD implanting centers in Canada were surveyed to assess complication rates as a result of generator replacements because of ICD advisories from October 2004 to October 2005. MAIN OUTCOME MEASURE: Complications associated with elective ICD generator replacement for current device advisories. RESULTS: At the 17 surveyed centers, 2915 patients had recall devices, including 533 (18.3%) who had advisory ICDs replaced a mean (SD) of 26.5 (11.5) months after their initial implant. Of these patients, 66% had a secondary prevention ICD, and 45% had received a previous appropriate shock. During a mean (SD) of 2.7 (2.8) months' follow-up after ICD generator replacement, complications occurred in 43 patients (8.1%). Major complications attributable to advisory device replacement requiring reoperation occurred in 31 patients (5.8%), with death in 2 patients after extraction for pocket infection. Minor complications occurred in 12 patients (2.3%). There were 3 (0.1%) advisory-related device malfunctions reported, without clinical consequences. CONCLUSIONS: ICD generator replacement in patients with advisory devices is associated with a substantial rate of complications, including death. These complications need to be considered in the development of guidelines determining the appropriate treatment of patients with advisory devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.008
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.278
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations286
Published2006
Admission routes2
Has abstractyes

Explore more

Same venueJAMASame topicCardiac pacing and defibrillation studiesFrench-language works237,207