MétaCan
Menu
Back to cohort
Record W2028715361 · doi:10.1063/1.1150353

Efficiency and transient time studies of an electron cyclotron resonance ion source for radioactive ion beam production at ISAC/TRIUMF

2000· article· en· W2028715361 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueReview of Scientific Instruments · 2000
Typearticle
Languageen
FieldEngineering
TopicParticle accelerators and beam dynamics
Canadian institutionsTRIUMF
Fundersnot available
KeywordsIon sourceElectron cyclotron resonanceAtomic physicsIonIon beamMaterials scienceIon beam depositionBeam (structure)Ion gunIonizationCyclotronHighly charged ionPlasmaPhysicsNuclear physicsOptics

Abstract

fetched live from OpenAlex

A 2.45 GHz electron cyclotron resonance (ECR) ion source with a single mode resonator is being developed to produce high efficient single charged ion beams from exiguous gaseous elements. The source is intended to produce short and long half-life radioactive ion beams as well as stable ion beams for low and high energy experiments at ISAC [J. M. Poutissou, Proceedings of the ISAC Workshop (1994)]. It is obvious that for the radioactive ion beam production, the gas and ion transient time and the overall ionization efficiency are the most important parameters. The transient time is measured using ultrafast peizoelectric gas valve which could operate up to a frequency of 2 kHz. A unique feature of the source is that the plasma chamber is considerably smaller (∼170 times) than its resonance cavity in order to minimize the transient time. Quartz tubes with various diameters (5–20 mm) and 80 mm long are tested as the plasma chamber and the results are discussed. The effect of the transfer tube length, which links the target and the ion source on the transient time is also described. An axially symmetric five electrode extraction system containing three multiaperture electrodes was used to extract the beam. The source, including ECR coils and extraction system is placed in the middle of a 60 cm×60 cm×90 cm vacuum box to simulate the ISAC target module conditions. The preliminary results of the molecular and ion transient time studies, beam efficiency studies are also presented in this article.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.381
Threshold uncertainty score0.499

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.255
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it