MétaCan
Menu
Back to cohort
Record W2028981774 · doi:10.1002/jmri.22587

Quantitative assessment of cardiac output and left ventricular function by noninvasive phase‐contrast and cine MRI: Validation study with invasive pressure‐volume loop analysis in a swine model

2011· article· en· W2028981774 on OpenAlexafffund
Hung‐Yu Lin, Darren H. Freed, Trevor W.R. Lee, Rakesh C. Arora, Ayyaz Ali, Waiel Al-Moustadi, Bo Xiang, Fei Wang, Stephen Large, Scott B. King, Bogusław Tomanek, Ganghong Tian

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2011
Typearticle
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsSt. Boniface HospitalUniversity of ManitobaNational Research Council CanadaNational Research Council Institute for Biodiagnostics
FundersManitoba Medical Service Foundation
KeywordsDobutamineMagnetic resonance imagingMedicineCardiac function curveNuclear medicineCardiac outputInotropeCardiologyHemodynamicsRadiologyHeart failure

Abstract

fetched live from OpenAlex

PURPOSE: To validate noninvasive cardiac output measurements of phase-contrast magnetic resonance imaging (PC-MRI) and cine MRI using an invasive pressure-volume (PV) loop technique on a swine model. MATERIALS AND METHODS: We compared three methods for evaluating cardiac function at rest and under pharmaceutical low-dose inotropic infusion conditions: 1) phase-contrast MRI, 2) cine MRI, and 3) PV loop relationship. These measurements were made in 14 domestic pigs under rest conditions. Identical MRI acquisitions and PV loop analysis were performed on six pigs from the same group that received an infusion of dobutamine 2.5 μg/kg/min. Cardiac outputs from all measurements were analyzed and compared using linear regression and Bland-Altman analysis. RESULTS: Noninvasive PC-MRI and cine MRI did not show any significant differences compared to an invasive PV loop technique for measurement of cardiac output under both rest (PC-MRI, cine MRI, and PV loop, 3.17 ± 0.45, 3.18 ± 0.61, 3.45 ± 0.41 L/min, respectively) and pharmaceutical low-dose inotropic infusion conditions (PC-MRI, cine MRI, and PV loop, 4.78 ± 0.53, 4.7 ± 0.6, 4.96 ± 0.48 L/min, respectively). Statistical analysis showed good agreement of cardiac output measurements at rest (R(2) = 0.83) and under low-dose inotropic infusion conditions (R(2) = 0.74) using PC-MRI and PV loop techniques. Cardiac output measurement using cine MRI and PV loop techniques also showed good agreement at rest (R(2) = 0.85) and under low-dose inotropic infusion conditions (R(2) = 0.76). Furthermore, cardiac outputs determined with the three modalities showed good agreement over a wide range of heart rates (90-180 bpm). CONCLUSION: MRI can provide a reliable, noninvasive measurement of cardiac output that can be carried out without the complications that are inherent with current invasive procedures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.130
Threshold uncertainty score0.508

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.289
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicHemodynamic Monitoring and TherapyFrench-language works237,207