MétaCan
Menu
Back to cohort
Record W2029079114 · doi:10.1120/jacmp.v10i4.3056

Accuracy of automatic couch corrections with on‐line volumetric imaging<sup>*</sup>

2009· article· en· W2029079114 on OpenAlexaff
Winnie Li, D Moseley, Tony Manfredi, David A. Jaffray

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2009
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of TorontoPrincess Margaret Cancer Centre
Fundersnot available
KeywordsIsocenterImaging phantomNuclear medicineStandard deviationCone beam computed tomographyResidualMedicineComputer scienceMathematicsComputed tomographyRadiologyAlgorithm

Abstract

fetched live from OpenAlex

The purpose of this study was to characterize automatic remote couch adjustment and to assess the accuracy of automatic couch corrections following localization with cone-beam CT (CBCT). Automatic couch movement was evaluated through passive reflector markers placed on a phantom, tracked with an optical tracking system (OTS). Repeated couch movements in the lateral, cranial/caudal, and vertical directions were monitored through the OTS to assess velocity and response time. In conjunction with CBCT, remote table movement for patient displacements following initial setup was available on four linear accelerators (Elekta Synergy). After the initial CBCT scan assessment, patients with isocenter displacements that exceeded clinical protocol tolerances were corrected using remote automatic couch movement. A verification CBCT scan was acquired after any remote movements. These verification CBCT datasets were assessed for the following time periods: one month post clinical installation, and six months later to monitor remote couch correction stability. Residual error analysis was evaluated using the verification scans. The mean +/- standard deviations (mu +/- sigma) of couch movement based on phantom measurements with the OTS were 0.16 +/- 0.48 mm, 0.32 +/- 0.30 mm, 0.11 +/- 0.12 mm in the L/R, A/P, and S/I couch directions, respectively. The fastest maximum velocity was observed in the inferior direction at 10.5 mm/s, and the slowest maximum velocity in the left direction at 3.6 mm/s. From 1134 verification CBCT registrations for 207 patients, the residual error for each translational direction from each month evaluated are reported. The mu was less than 0.3 mm in all directions, and sigma was in the order of 1 mm. At a 3 mm threshold, 21 of the 1134 fractions (2%) exceeded tolerance, attributed to patient intrafraction movement. Remote automatic couch movement is reliable and effective for adjusting patient position with a precision of approximately 1mm. Patient residual error observed in this study demonstrates that displacement is minimal after remote couch adjustment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.976
Threshold uncertainty score0.682

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.359
Teacher spread0.340 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207