MétaCan
Menu
Back to cohort
Record W2029326622 · doi:10.1002/rcm.4806

Effect of solvent and electrospray mass spectrometer parameters on the charge state distribution of peptides – a case study using liquid chromatography/mass spectrometry method development for beta‐endorphin assay

2010· article· en· W2029326622 on OpenAlexaff
Amitha K. Hewavitharana, H. M. D. R. Herath, P. Nicholas Shaw, Peter J. Cabot, P. Kebarle

Bibliographic record

VenueRapid Communications in Mass Spectrometry · 2010
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsChemistryDeprotonationElectrosprayMass spectrometrySolventElectrospray ionizationMoleculeIonAnalytical Chemistry (journal)ChromatographyOrganic chemistry

Abstract

fetched live from OpenAlex

Beta-endorphin was used as a model peptide to study the effect of solvent and electrospray mass spectrometer parameters in the optimisation of an assay method for multiply charged compounds using liquid chromatography/mass spectrometry (LC/MS). Unlike with singly charged compounds, the charge state distribution has a significant impact in the method development of multiply charged compounds such as peptides. Using a 50% acetonitrile/water solvent mixture, we found that the ion spray voltage had no influence on the charge state distribution. However, increasing declustering potential led to deprotonation of the higher charge states of the peptide thus causing a shift to lower charge states. The mechanism leading to the deprotonation was examined. It was concluded that the deprotonation is due to endoergic proton transfer from the peptide to solvent molecules clustered to the peptide that occurs in the declustering region. The extent of deprotonation increases with increasing proton affinity of the molecules of the non-aqueous solvent component used. Thus, if desired, deprotonation can be avoided by selecting a low proton affinity solvent such as methanol. The focusing potential was also found to have a great influence on the charge state distribution observed. The results of this study enabled us to select the optimum ion to be used in single ion/reaction monitoring mode. They also provided the most favourable parameter values to be used in the method to obtain the best sensitivity for the ion of choice. The results demonstrate the importance of considering the charge state distribution in the optimisation of electrospray LC/MS methods for multiply charged compounds.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.321
Teacher spread0.297 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueRapid Communications in Mass SpectrometrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207