MétaCan
Menu
Back to cohort
Record W2029657660 · doi:10.1002/mrm.21552

Removing undersampling artifacts in DCE‐MRI studies using independent components analysis

2008· article· en· W2029657660 on OpenAlexaff
Anne L. Martel, Rachel W. Chan, Elizabeth Ramsay, Donald B. Plewes

Bibliographic record

VenueMagnetic Resonance in Medicine · 2008
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsHealth Sciences CentreUniversity of TorontoSunnybrook Health Science Centre
Fundersnot available
KeywordsUndersamplingStreakComputer scienceArtificial intelligenceImage resolutionProjection (relational algebra)Artifact (error)Contrast (vision)Temporal resolutionPattern recognition (psychology)Independent component analysisAutoencoderComputer visionArtificial neural networkAlgorithmChemistry

Abstract

fetched live from OpenAlex

In breast MRI mammography both high temporal resolution and high spatial resolution have been shown to be important in improving specificity. Adaptive methods such as projection reconstruction time-resolved imaging of contrast kinetics (PR-TRICKS) allow images to be reconstructed at various temporal and spatial resolutions from the same data set. The main disadvantage is that the undersampling, which is necessary to produce high temporal resolution images, leads to the presence of streak artifacts in the images. We present a novel method of removing these artifacts using independent components analysis (ICA) and demonstrate that this results in a significant improvement in image quality for both simulation studies and for patient dynamic contrast-enhanced (DCE)-MRI images. We also investigate the effect of artifacts on two quantitative measures of contrast enhancement. Using simulation studies we demonstrate that streak artifacts lead to pronounced periodic oscillations in pixel concentration curves which, in turn, lead to increased errors and introduce bias into heuristic measurements. ICA filtering significantly reduces this bias and improves accuracy. Pharmacokinetic modeling was more robust and there was no evidence of bias due to the presence of streak artifacts. ICA filtering did not significantly reduce the errors in the estimated pharmacokinetic parameters; however, the chi-squared error was greatly reduced after ICA filtering.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.024
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.006
Threshold uncertainty score0.032

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.024
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.002
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.168
GPT teacher head0.403
Teacher spread0.235 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207