MétaCan
Menu
Back to cohort
Record W2031151303 · doi:10.1097/hjh.0b013e32831b9e6b

Use of automated office blood pressure measurement to reduce the white coat response

2009· article· en· W2031151303 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueJournal of Hypertension · 2009
Typearticle
Languageen
FieldMedicine
TopicBlood Pressure and Hypertension Studies
Canadian institutionsHealth Sciences CentreSunnybrook Health Science CentreUniversity of Toronto
Fundersnot available
KeywordsMedicineWhite coatWhite coat hypertensionBlood pressureCoatInternal medicineComposite materialAmbulatory blood pressure

Abstract

fetched live from OpenAlex

OBJECTIVE: To examine the possibility of reducing the white coat response using an automated sphygmomanometer designed for office use, the BpTRU. Consecutive patients referred from physicians in the community to an ambulatory blood pressure (ABP) monitoring unit in an academic hospital were included in the study. PARTICIPANTS AND METHODS: A total of 309 patients referred for diagnosis or management of hypertension were studied. Differences between mean awake ABP and BP readings taken by the patient's own physician using a manual sphygmomanometer or the automated BpTRU device with the patient resting alone in the ABP monitoring unit were compared. RESULTS: BP recorded in the examining room using an automated device (132 +/- 19/75 +/- 12) was similar to the mean awake ABP (134 +/- 12/77 +/- 10) with both values being lower (P < 0.001) than the BP recorded on a routine visit to the patient's own family physician (152 +/- 18/87 +/- 11). The coefficient of correlation between the systolic/diastolic ABP and the automated office BP (r = 0.62/0.72) was higher (P < 0.001) than with the family physician's manual BP (r = 0.32/0.48). The prevalence of white coat hypertension in untreated patients (n = 146) was significantly (P < 0.001) lower with automated office BP (16%) compared with the routine family physician BP (55%). CONCLUSION: The white coat response associated with office BP measurements can be virtually eliminated by recording BP with the automated BpTRU device with patients resting alone in a quiet examining room.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.550
Threshold uncertainty score0.431

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.100
GPT teacher head0.288
Teacher spread0.188 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it