MétaCan
Menu
Back to cohort
Record W2031539031 · doi:10.1002/ccd.21890

Time dependent vascular and myocardial responses of a second generation, small vessel, paclitaxel‐eluting stent platform

2008· article· en· W2031539031 on OpenAlexaff
Craig A. Thompson, Barbara Huibregtse, B. Poff, Gregory J. Wilson

Bibliographic record

VenueCatheterization and Cardiovascular Interventions · 2008
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsHospital for Sick Children
Fundersnot available
KeywordsMedicineStentConventional PCIPercutaneous coronary interventionThrombusCardiologyCoronary arteriesPaclitaxelRadiologyInternal medicineMyocardial infarctionArtery

Abstract

fetched live from OpenAlex

OBJECTIVES: The purpose of this study was to evaluate the time-dependent vascular and myocardial responses to a second-generation, small vessel (< or =2.5 mm) paclitaxel-eluting stent (PES) platform. BACKGROUND: Small caliber coronary vessels present complex challenges for percutaneous coronary intervention (PCI) and are associated with lower technical success and inferior long-term efficacy. A next-generation, highly deliverable PES may improve clinical outcomes in small vessels. METHODS: Sixty single stents were implanted in noninjured coronary arteries in 30 domestic swine (one TAXUS Liberté small vessel PES (svPES) and one Liberté small vessel bare metal stent (svBMS) in each animal). Ten animals each were allocated to 30-, 90-, and 180-day follow-up groups; final quantitative angiography and necropsy were performed. Samples of myocardium, liver, and kidney were processed and evaluated for pathology. Radiography and either histopathology or scanning electron microscopy were performed on all the explanted stented vessels. RESULTS: There were no stent-related deaths or downstream myocardial pathology. Both the svPES stent and its svBMS control demonstrated complete strut tissue coverage and complete endothelialization at all timepoints, and there was no evidence of macro- or microscopic thrombus or stent fracture. Medial smooth muscle cell content was markedly reduced in all the svPES groups compared with that in the svBMS controls. CONCLUSIONS: The small diameter paclitaxel-eluting TAXUS Liberté stent has a safe and predictable biologic vascular response in the noninjured swine model. This device warrants further investigation targeting the currently poorly met clinical need for small vessel PCI.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.652
Threshold uncertainty score0.693

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.262
Teacher spread0.211 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueCatheterization and Cardiovascular InterventionsSame topicCoronary Interventions and DiagnosticsFrench-language works237,207