MétaCan
Menu
Back to cohort
Record W2031557018 · doi:10.1118/1.3700171

Exploring <sup>57</sup>Co as a new isotope for brachytherapy applications

2012· article· en· W2031557018 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueMedical Physics · 2012
Typearticle
Languageen
FieldPhysics and Astronomy
TopicRadioactive Decay and Measurement Techniques
Canadian institutionsUniversité LavalCentre hospitalier universitaire de Québec
FundersCanadian Cancer Society Research Institute
KeywordsBrachytherapyPhotonMonte Carlo methodDosimetryPhysicsRadionuclideRadiationIsotopeCobalt-60Gamma rayNuclear medicineMaterials scienceRadiochemistryAtomic physicsOpticsChemistryNuclear physicsIrradiationRadiation therapyMathematics

Abstract

fetched live from OpenAlex

PURPOSE: The characteristics of the radionuclide (57)Co make it interesting for use as a brachytherapy source. (57)Co combines a possible high specific activity with the emission of relatively low-energy photons and a half-life (272 days) suitable for regular source exchanges in an afterloader. (57)Co decays by electron capture to the stable (57)Fe with emission of 136 and 122 keV photons. METHODS: A hypothetical (57)Co source based on the Flexisource brachytherapy encapsulation with the active core set as a pure cobalt cylinder (length 3.5 mm and diameter 0.6 mm) covered with a cylindrical stainless-steel capsule (length 5 mm and thickness 0.125 mm) was simulated using Geant4 Monte Carlo (MC) code version 9.4. The radial dose function, g(r), and anisotropy function F(r,θ), for the line source approximation were calculated following the TG-43U1 formalism. The results were compared to well-known (192)Ir and (125)I radionuclides, representing the higher and the lower energy end of brachytherapy, respectively. RESULTS: The mean energy of photons in water, after passing through the core and the encapsulation material was 123 keV. This hypothetical (57)Co source has an increasing g(r) due to multiple scatter of low-energy photons, which results in a more uniform dose distribution than (192)Ir. CONCLUSIONS: (57)Co has many advantages compared to (192)Ir due to its low-energy gamma emissions without any electron contamination. (57)Co has an increasing g(r) that results in a more uniform dose distribution than (192)Ir due to its multiple scattered photons. The anisotropy of the (57)Co source is comparable to that of (192)Ir. Furthermore, (57)Co has lower shielding requirements than (192)Ir.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.972
Threshold uncertainty score0.613

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.102
GPT teacher head0.331
Teacher spread0.229 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it