Accounting for low-frequency synchrotron X-ray beam position fluctuations for dynamic visualizations
Bibliographic record
Abstract
Synchrotron X-ray radiography on beamline 05B1-1 at the Canadian Light Source Inc. was employed to study dynamic liquid water transport in the porous electrode materials of polymer electrolyte membrane fuel cells. Dynamic liquid water distributions were quantified for each radiograph in a sequence, and non-physical liquid water measurements were obtained. It was determined that the position of the beam oscillated vertically with an amplitude of ~25 µm at the sample and a frequency of ~50 mHz. In addition, the mean beam position moved linearly in the vertical direction at a rate of 0.74 µm s(-1). No evidence of horizontal oscillations was detected. In this work a technique is presented to account for the temporal and spatial dependence of synchrotron beam intensity, which resulted in a significant reduction in false water thickness. This work provides valuable insight into the treatment of radiographic time-series for capturing dynamic processes from synchrotron radiation.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.005 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.004 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".