MétaCan
Menu
Back to cohort
Record W2032653550 · doi:10.1118/1.4816677

HDR brachytherapy of rectal cancer using a novel grooved‐shielding applicator design

2013· article· en· W2032653550 on OpenAlexaff
Matthew J. Webster, Slobodan Dević, T. Vuong, Dae Yup Han, Dongju Choi, Bongyong Song, William Y. Song

Bibliographic record

VenueMedical Physics · 2013
Typearticle
Languageen
FieldMedicine
TopicColorectal Cancer Surgical Treatments
Canadian institutionsMcGill UniversityJewish General Hospital
Fundersnot available
KeywordsBrachytherapyElectromagnetic shieldingCollimated lightDosimetryImaging phantomDwell timeNuclear medicineMaterials scienceBiomedical engineeringMedicineRadiation therapyOpticsRadiologyLaserPhysics

Abstract

fetched live from OpenAlex

PURPOSE: The aim of this work was to design a novel high-dose rate (HDR) ((192)Ir) brachytherapy applicator for treatment of rectal carcinomas that uses tungsten shielding for possibly improved dosimetric results over commercial brachytherapy applicator(s). METHODS: A set of 15 single-depth applicators and one dual-depth applicator were designed and simulated using Monte Carlo (MCNPX). All applicators simulated were high-density tungsten alloy cylinders, 16-mm in diameter, and 60-mm long, with longitudinal grooves within which an (192)Ir source can be placed. The single-depth designs varied regarding the number and depth of these grooves, ranging from 8 to 16 and 1-mm to 3-mm, respectively. The dual-depth design had ten channels, each of which had two depths at which the source could be placed. Optimized treatment plans were generated for each design on data from 13 treated patients (36 fractions) with asymmetrical clinical target volumes (CTVs). All results were compared against the clinically treated plans which used intracavitary mold applicator (ICMA), as well as a recently designed, highly automated, and collimated intensity modulation device named dynamic modulated brachytherapy (DMBT) device. RESULTS: All applicator designs outperformed the ICMA in every calculated dosimetric criteria, except the total dwell times (∼30% increase). There were clear, but relative, tradeoffs regarding both the number of channels and the depth of each channel. Overall, the 12-channel, 1-mm depth, and 14-channel 2-mm depth designs had the best results of the simpler designs, sparing the healthy rectal tissues the most while achieving comparable CTV coverage with the dose heterogeneity index and lateral spill doses improving by over 10% and the contralateral healthy rectum dose dropping over 30% compared to ICMA. The ten-channel dual-depth design outperformed each single-depth design, yielding the best coverage and sparing. CONCLUSIONS: New grooved tungsten HDR-brachytherapy devices have been designed and simulated. The results of this work attest to the capability of these new, highly anisotropic, intelligently shielded applicators to limit dose to healthy tissues while maintaining a conformal prescription dose to the CTV.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.074
GPT teacher head0.343
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations30
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicColorectal Cancer Surgical TreatmentsFrench-language works237,207