MétaCan
Menu
Back to cohort
Record W2032739975 · doi:10.1002/nau.10156

Development of a dynamometer for measuring the isometric force of the pelvic floor musculature

2003· article· en· W2032739975 on OpenAlexafffund
Chantale Dumoulin, Daniel Bourbonnais, Marie‐Claude Lemieux

Bibliographic record

VenueNeurourology and Urodynamics · 2003
Typearticle
Languageen
FieldMedicine
TopicPelvic floor disorders treatments
Canadian institutionsComputer Research Institute of MontréalHôpital Maisonneuve-RosemontUniversité de MontréalMontreal Heart Institute
FundersCanadian Institutes of Health Research
KeywordsDynamometerRepeatabilityIsometric exerciseMedicineStrain gaugeCalibrationPelvic floorPelvic Floor MuscleLinearityHysteresisBiomedical engineeringOrthodonticsMechanical engineeringPhysical therapySurgeryStructural engineeringMathematicsStatisticsPhysicsElectrical engineeringEngineering

Abstract

fetched live from OpenAlex

AIMS: The aim of this study was to design and develop a dynamometer providing a direct measurement of pelvic floor muscle (PFM) strength. MATERIALS AND METHODS: Two pairs of strain gauges were mounted on the moveable branch of a dynamometric speculum allowing measurements at different vaginal apertures. Linearity, repeatability, independence of the site of application of the resultant force to the lower branch of the speculum and hysteresis were tested by means of in vitro calibration studies. RESULTS: The linearity proved excellent over a range of 0-15 N with regression coefficients close to unity between imposed loads and voltage outputs. The slopes and intercepts of the regression lines were not significantly different between repeated sessions, indicating the high reliability of these in vitro measurements. The slopes and intercepts of the calibrations, using the same repertoire of loads imposed at three locations on the moving branch of the dynamometer, were not significantly different, confirming that the force measurement is independent of the site of the force application. Hysteresis was considered to be minimal. CONCLUSIONS: This study demonstrates that the dynamometer provides reliable measurements. The new device thus appears to have conceptual and measuring advantages over conventional methods and seems to be a very promising instrument for measuring pelvic floor strength.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.235
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations110
Published2003
Admission routes2
Has abstractyes

Explore more

Same venueNeurourology and UrodynamicsSame topicPelvic floor disorders treatmentsFrench-language works237,207