MétaCan
Menu
Back to cohort
Record W2032739975 · doi:10.1002/nau.10156

Development of a dynamometer for measuring the isometric force of the pelvic floor musculature

2003· article· en· W2032739975 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueNeurourology and Urodynamics · 2003
Typearticle
Languageen
FieldMedicine
TopicPelvic floor disorders treatments
Canadian institutionsComputer Research Institute of MontréalHôpital Maisonneuve-RosemontUniversité de MontréalMontreal Heart Institute
FundersCanadian Institutes of Health Research
KeywordsDynamometerRepeatabilityIsometric exerciseMedicineStrain gaugeCalibrationPelvic floorPelvic Floor MuscleLinearityHysteresisBiomedical engineeringOrthodonticsMechanical engineeringPhysical therapySurgeryStructural engineeringMathematicsStatisticsPhysicsElectrical engineeringEngineering

Abstract

fetched live from OpenAlex

AIMS: The aim of this study was to design and develop a dynamometer providing a direct measurement of pelvic floor muscle (PFM) strength. MATERIALS AND METHODS: Two pairs of strain gauges were mounted on the moveable branch of a dynamometric speculum allowing measurements at different vaginal apertures. Linearity, repeatability, independence of the site of application of the resultant force to the lower branch of the speculum and hysteresis were tested by means of in vitro calibration studies. RESULTS: The linearity proved excellent over a range of 0-15 N with regression coefficients close to unity between imposed loads and voltage outputs. The slopes and intercepts of the regression lines were not significantly different between repeated sessions, indicating the high reliability of these in vitro measurements. The slopes and intercepts of the calibrations, using the same repertoire of loads imposed at three locations on the moving branch of the dynamometer, were not significantly different, confirming that the force measurement is independent of the site of the force application. Hysteresis was considered to be minimal. CONCLUSIONS: This study demonstrates that the dynamometer provides reliable measurements. The new device thus appears to have conceptual and measuring advantages over conventional methods and seems to be a very promising instrument for measuring pelvic floor strength.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.166
Threshold uncertainty score0.323

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.235
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it