MétaCan
Menu
Back to cohort
Record W2032820816 · doi:10.1118/1.598962

A practical technique for verification of three‐dimensional conformal dose distributions in stereotactic radiosurgery

2000· article· en· W2032820816 on OpenAlexaff
James L. Robar, B. G. Clark

Bibliographic record

VenueMedical Physics · 2000
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of British ColumbiaBC Cancer Agency
Fundersnot available
KeywordsRadiosurgeryImaging phantomDICOMMonte Carlo methodConformal mapNuclear medicinePixelDosimetryMedical imagingOpticsPhysicsComputer scienceArtificial intelligenceMathematicsRadiation therapyMedicineRadiologyGeometry

Abstract

fetched live from OpenAlex

The trend toward conformal techniques in stereotactic radiosurgery necessitates an accurate and practical method for verification of irregular three-dimensional dose distributions. This work presents the design and evaluation of a phantom system facilitating the measurement of conformal dose distributions using one or more arrays of up to 20 radiographic films separated by 3.2 mm-thick tissue-equivalent spacers. Using Electron Gamma Shower version 4 (EGS4) Monte Carlo simulation, we show that for 6 MV radiosurgical photon beams this arrangement preserves tissue-equivalence to within 1%. The phantom provides 0.25 mm in-plane spatial resolution and multiple sets of films may be used to resample the dose volume in orthogonal planes. Dedicated software has been developed to automate the process of ordering and orienting of scanned film images, conversion of scanned pixel value to dose, resampling of one or more sets of film images and subsequent export of images in DICOM format for coregistration of planned and measured dose volumes. Calculated and measured isodose surfaces for a simple, circular-beam treatment agree to within 1.5 mm throughout the dose volume. For conformal radiosurgical applications, the measured and planned dose distributions agree to within the uncertainty of the manufacture of irregularly shaped collimators. The sensitivity of this technique to minor spatial inaccuracies in beam shaping is also demonstrated.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.949
Threshold uncertainty score0.882

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.319
Teacher spread0.299 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations35
Published2000
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207