MétaCan
Menu
Back to cohort
Record W2033201465 · doi:10.1016/j.plabm.2015.02.001

A practical approach for the validation and clinical implementation of a high-sensitivity cardiac troponin I assay across a North American city

2015· article· en· W2033201465 on OpenAlexafffund
Peter A. Kavsak, John Beattie, Robin Pickersgill, L Ford, Nadia Caruso, Lorna Clark

Bibliographic record

VenuePractical Laboratory Medicine · 2015
Typearticle
Languageen
FieldMedicine
TopicAcute Myocardial Infarction Research
Canadian institutionsHamilton General HospitalSt. Joseph's HospitalMcMaster Children's HospitalJuravinski HospitalMcMaster UniversityHamilton Regional Laboratory Medicine Program
FundersAbbott DiagnosticsMcMaster UniversityAbbott Laboratories
KeywordsTroponin ICoefficient of variationDetection limitMedicineStatisticsInternal medicineNuclear medicineMathematics

Abstract

fetched live from OpenAlex

Despite several publications on the analytical performance of high-sensitivity cardiac troponin (hs-cTn) assays, there has been little information on how laboratories should validate and implement these assays into clinical service. Our study provides a practical approach for the validation and implementation of a hs-cTn assay across a large North American City. Validation for the Abbott ARCHITECT hs-cTnI assay (across 5 analyzers) consisted of verification of limit of blank (LoB), precision (i.e., coefficient of variation; CV) testing at the reported limit of detection (LoD) and within and outside the 99th percentile, linearity testing, cTnI versus hs-cTnI patient comparison within and between analyzers (Passing and Bablok and non-parametric analyses). Education, clinical communications, and memorandums were issued in advance to inform all staff across the city as well as a selected reminder the day before live-date to important users. All hospitals switched to the hs-cTnI assay concurrently (the contemporary cTnI assay removed) with laboratory staff instructed to repeat samples previously measured with the contemporary cTnI assay with the hs-cTnI assay only by physician request. Across the 5 analyzers and 6 reagent packs the overall LoB was 0.6 ng/L (n=60) with a CV of 33% at an overall mean of 1.2 ng/L (n=60; reported LoD=1.0 ng/L), with linearity demonstrated from 45,005 ng/L to 1.1 ng/L. Precision testing with a normal patient-pool QC material (mean range across 5 analyzers was 3.9–4.4 ng/L) yielded a range of CVs from 7% to 10% (within-run) and CVs from 7% to 18% (between-run) with the high patient-pool QC material (mean range across 5 analyzers was 29.6–36.3 ng/L) yielding a range of CVs from 2% to 5% (within-run) and CVs from 4% to 8% (between-run). There was agreement between hs-cTnI versus cTnI with the patient samples (slope ranges: 0.89–1.03; intercept ranges: 1.9–3.8 ng/L), however, the median CV on patient samples <100 ng/L across the analyzers was 5.6% for hs-cTnI versus 18.7% for the contemporary assay (p<0.001). Following the switch to hs-cTnI testing, no requests for repeat measurements were received. Validation and implementation of hs-cTnI testing across multiple sites requires collaboration within the laboratories and between hospital laboratories and clinical staff.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.075
metaresearch head score (Gemma)0.075
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.075
Threshold uncertainty score0.396

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0750.075
Meta-epidemiology (narrow)0.0020.002
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.002
Science and technology studies0.0070.003
Scholarly communication0.0060.004
Open science0.0060.010
Research integrity0.0050.005
Insufficient payload (model declined to judge)0.0100.007

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.139
GPT teacher head0.499
Teacher spread0.360 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations39
Published2015
Admission routes2
Has abstractyes

Explore more

Same venuePractical Laboratory MedicineSame topicAcute Myocardial Infarction ResearchFrench-language works237,207