MétaCan
Menu
Back to cohort
Record W2033272341 · doi:10.2106/jbjs.f.01224

Locking Compression Plate Fixation of Vancouver Type-B1 Periprosthetic Femoral Fractures

2007· article· en· W2033272341 on OpenAlexaboutno aff
Martín Buttaro, Germán L. Farfalli, M. Paredes Núñez, Fernando Comba, Francisco Piccaluga

Bibliographic record

VenueJournal of Bone and Joint Surgery · 2007
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsPeriprostheticMedicineSurgeryFixation (population genetics)ProsthesisInternal fixationFemoral fractureReduction (mathematics)ArthroplastyFemur

Abstract

fetched live from OpenAlex

BACKGROUND: Fractures occurring at or near the distal tip of a hip prosthesis with a stable femoral stem (Vancouver type-B fractures) are associated with many complications because of the inherently unstable fracture pattern. Locking compression plates use screws that lock into the plate allowing multiple points of unicortical fixation. Such unicortical fixation may lower the risk of damage to the cement mantle or a stable femoral stem during the treatment of a periprosthetic femoral fracture. The purpose of this study was to analyze clinically and radiographically a group of patients with a Vancouver type-B1 periprosthetic femoral fracture treated with open reduction and internal fixation with use of a locking compression plate. METHODS: Fourteen consecutive patients (fourteen hips) with a Vancouver type-B1 periprosthetic femoral fracture were treated with a locking compression plate. There were five men and nine women with an average age of sixty-eight years at the time of fracture. All of the fractures occurred after a total hip arthroplasty performed with cement, and eleven of the arthroplasties were revisions. In addition to the plate, cortical strut allografts were used to stabilize five fractures. The patients were assessed clinically and radiographically. RESULTS: The average duration of follow-up was twenty months. Eight fractures healed uneventfully at an average of 5.4 months. Three treatment constructs failed with fracture of the plate within twelve months after surgery. An additional three constructs also failed because of plate pullout. All failures except one occurred in constructs in which a cortical strut allograft had not been utilized. CONCLUSIONS: On the basis of the high failure rate in this series of patients, locking compression plates do not appear to offer advantages over other types of plates in the treatment of type-B1 periprosthetic femoral fractures. Despite the potential to preserve the cement mantle, the locked screws did not appear to offer good pullout resistance in this fracture type. We believe that supplementation with strut allografts should be used routinely if this type of locking compression plate is selected to treat these fractures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.343
Threshold uncertainty score0.219

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.273
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations152
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Bone and Joint SurgerySame topicOrthopaedic implants and arthroplastyFrench-language works237,207