MétaCan
Menu
Back to cohort
Record W2033521410 · doi:10.1118/1.3681949

Least-error projection sorting to optimize retrospectively gated cardiac micro-CT of free-breathing mice

2012· article· en· W2033521410 on OpenAlexaff
Stephen E. J. Armitage, Steven I. Pollmann, Sarah A. Detombe, Maria Drangova

Bibliographic record

VenueMedical Physics · 2012
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsRobarts Clinical TrialsWestern University
Fundersnot available
KeywordsImaging phantomScannerImage qualityIterative reconstructionImage resolutionRotation (mathematics)Projection (relational algebra)Optical transfer functionTomographyDetectorComputer scienceArtificial intelligenceOpticsComputer visionPhysicsAlgorithmImage (mathematics)

Abstract

fetched live from OpenAlex

PURPOSE: To develop and characterize a technique for optimizing image quality by eliminating streaking artifacts in retrospectively gated microcomputed tomography (micro-CT) images of mice caused by insufficient and irregular angular sampling. METHODS: A least-error sorting technique was developed to minimize streak artifacts in retrospectively gated cardiac micro-CT images. To ensure complete filling of projection space, for each angular position, the projection acquired closest to the desired cardiac phase is used to reconstruct a volumetric image. An acrylic slanted-edge phantom undergoing cyclic motion was used to characterize the system's resolution. The phantom was scanned using a volumetric micro-CT scanner equipped with a flat-panel detector mounted on a slip-ring gantry. Projection images of the moving phantom were collected over a period of 60 s using a variety of acquisition protocols with the rotation period of the gantry ranging from 1 to 5 s. The modulation transfer function (MTF) of the reconstructed images was measured for many combinations of acquisition and reconstruction parameters. The use of the least-error technique was also demonstrated in vivo. RESULTS: The motion blurring introduced into the images at physiologically significant velocities of 6 cm∕s agreed well with predicted values; limiting resolution (frequency at 10% MTF) degraded from 2.5 to 1.0 mm(-1) for a velocity of 6 cm∕s and 5 s∕rotation gantry speed. Faster gantry rotation speeds led to improved temporal resolution but the scanner's data storage and transfer rates and field of view limitations made scanning at gantry speeds faster than 2 s∕rotation impractical. CONCLUSIONS: The least-error technique effectively eliminates streaking artifact caused by missing views and allows for optimization of image quality in retrospectively gated micro-CT.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.409
Threshold uncertainty score0.572

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.327
Teacher spread0.296 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207