Magnetic Resonance Imaging Clarity of the Bryan®, Prodisc-C®, Prestige LP®, and PCM® Cervical Arthroplasty Devices

2007· article· en· W2033812722 on OpenAlexaff
Lali H.S. Sekhon, Neil Duggal, James J. Lynch, Regis W. Haid, John G. Heller, K. Daniel Riew, Kevin Seex, Paul A. Anderson

Bibliographic record

VenueSpine · 2007
Typearticle
Languageen
FieldMedicine
TopicCervical and Thoracic Myelopathy
Canadian institutionsWestern UniversityLondon Health Sciences Centre
Fundersnot available
KeywordsMedicineArthroplastyImplantMagnetic resonance imagingSurgeryOrthopedic surgeryVisual analogue scaleRadiology

Abstract

fetched live from OpenAlex

STUDY DESIGN: Prospective, randomized, controlled and double-blinded study on imaging of artificial discs. OBJECTIVE: The purpose of this study is to compare postoperative imaging characteristics of the 4 currently available cervical arthroplasty devices at the level of implantation and at adjacent levels. SUMMARY OF BACKGROUND DATA: Cervical arthroplasty is being performed increasingly frequently for degenerative disc disease and, in most cases, with frank neural compression. Unlike lumbar arthroplasty, performed mainly for axial back pain, decompression of neural elements may need to be confirmed with postoperative imaging after cervical arthroplasty. METHODS: Preoperative and postoperative magnetic resonance imaging scans of 20 patients who had undergone cervical arthroplasty were assessed for imaging quality. Five cases each of the Bryan (Medtronic Sofamor Danek, Memphis, TN), Prodisc-C (Synthes Spine, Paoli, PA), Prestige LP (Medtronic Sofamor Danek), and PCM devices (Cervitech, Rockaway, NJ) were analyzed. Six blinded spinal surgeons scored twice sagittal and axial T2-weighted images using the Jarvik 4-point scale. Statistical analysis was performed comparing quality before surgery and after disc implantation at the operated and adjacent levels and between implant types. RESULTS.: Moderate intraobserver and interobserver reliability was noted. Preoperative images of patients in all implant groups had high-quality images at operative and adjacent levels. The Bryan and Prestige LP devices allowed satisfactory visualization of the canal, exit foramina, cord, and adjacent levels after arthroplasty. Visualization was significantly impaired in all PCM and Prodisc-C cases at the operated level in both the spinal canal and neural foramina. At the adjacent levels, image quality was statistically poorer in the PCM and Prodisc-C than those of Prestige LP or Bryan. CONCLUSIONS.: Postoperative visualization of neural structures and adjacent levels after cervical arthroplasty is variable among current available devices. Devices containing nontitanium metals (cobalt-chrome-molybdenum alloys in the PCM and Prodisc-C) prevent accurate postoperative assessment with magnetic resonance imaging at the surgical and adjacent levels. Titanium devices, with or without polyethylene (Bryan disc or Prestige LP), allow for satisfactory monitoring of the adjacent and operated levels. This information is crucial for any surgeon who wishes to assess adequacy of neural decompression and where monitoring of adjacent levels is desired.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.405
Threshold uncertainty score0.335

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.262
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations72
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueSpineSame topicCervical and Thoracic MyelopathyFrench-language works237,207