MétaCan
Menu
Back to cohort
Record W2034596326 · doi:10.1109/iembs.2006.260298

Hardware Acceleration for Real Time Simulation of Physiological Systems

2006· article· en· W2034596326 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicReal-time simulation and control systems
Canadian institutionsUniversité LavalCisco Systems (Canada)
FundersXilinx
KeywordsComputer scienceAccelerationSimulationReal-time simulationInterface (matter)Medical simulationEmbedded systemReal-time computingOperating system

Abstract

fetched live from OpenAlex

Testing of medical equipment such as pacemaker is a critical task, because any malfunction may cause patient death or serious and long-lasting health consequences. Thus, device behavior under normal functioning conditions as well as under faulty conditions should be tested as thoroughly as possible under the project's budget. This paper presents a real-time digital simulator (DRTS) for possible use in testing of medical devices. The simulator runs a model of a physiological system (an organ or a group of organs) in real time and uses A/D and D/A cards to interface the simulation results to real medical equipment. With this simulator, the tests can be made as thorough as needed without much increase in cost.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.450
Threshold uncertainty score0.275

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.238
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Quick stats

Citations14
Published2006
Admission routes1
Has abstractyes

Explore more

Same topicReal-time simulation and control systemsFrench-language works237,207