MétaCan
Menu
Back to cohort
Record W2034685127 · doi:10.1117/12.841021

Femtosecond photoacoustics: integrated two-photon fluorescence and photoacoustic microscopy

2010· article· en· W2034685127 on OpenAlexaff
M.E. van Raaij, Mike Lee, Emmanuel Chérin, Bojana Stefanovic, F. Stuart Foster

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2010
Typearticle
Languageen
FieldEngineering
TopicPhotoacoustic and Ultrasonic Imaging
Canadian institutionsSunnybrook Health Science Centre
Fundersnot available
KeywordsPhotoacoustic imaging in biomedicineFemtosecondFluorescenceMicroscopyTwo-photon excitation microscopyMaterials scienceFluorescence microscopeMultiphoton fluorescence microscopePhotonOpticsOptoelectronicsLaserPhysics

Abstract

fetched live from OpenAlex

Conventional photoacoustic imaging systems excite a photoacoustic wave by illuminating an area on the order of square centimeters with millijoule laser pulses. Spatial resolution is then determined by the ultrasound transducer and is typically on the order of 100 μm. We report on a system that focuses femtosecond, nanojoule pulses to a spot with a diameter of ~ 1 μm to perform laser-scanning photoacoustics with micrometer resolution. Near-infrared femtosecond laser pulses with a pulse energy of 2.4 nanojoules excite a train of photoacoustic waves at the repetition rate of the pulsed laser (80 MHz). These photoacoustic waves are detected by an unfocused single-element ultrasound transducer tuned to 80 MHz. A radiofrequency lock-in amplifier recovers the amplitude of the frequency component of the photoacoustic signal at the pulse repetition frequency. This amplitude is an indicator of the absorption coefficient of the sample at the laser focus and at the laser wavelength. Initial experiments using a graphite rod as absorber reproducibly yield signals in the 0.2 - 2 microvolt range with a signal-to-noise ratio of 18 dB, recovered from 10 mV of broadband noise. The photoacoustic imaging system is integrated in a commercial laser-scanning two-photon fluorescence microscope, enabling simultaneous three-dimensional fluorescence- and photoacoustic imaging. One major application will be to image both morphology and oxygen saturation of microvasculature in the cerebral cortex of anesthetized rodents in vivo in the context of tumor angiogenesis. In this paper we describe the physics of femtosecond photoacoustics and demonstrate initial results.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.347
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.218
Teacher spread0.212 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicPhotoacoustic and Ultrasonic ImagingFrench-language works237,207