MétaCan
Menu
Back to cohort
Record W2034703003 · doi:10.1118/1.4822514

Fully 3D iterative CT reconstruction using polar coordinates

2013· article· en· W2034703003 on OpenAlexafffund
Christian Thibaudeau, Jean‐Daniel Leroux, Réjean Fontaine, Roger Lecomte

Bibliographic record

VenueMedical Physics · 2013
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsCentre Hospitalier Universitaire de SherbrookeUniversité de Sherbrooke
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health Research
KeywordsIterative reconstructionPolar coordinate systemComputed tomographyMedical imagingIterative methodPolarComputer visionComputer scienceArtificial intelligenceAlgorithmPhysicsMathematicsRadiologyGeometryMedicine

Abstract

fetched live from OpenAlex

PURPOSE: This paper demonstrates the feasibility of fully 3D iterative computed tomography reconstruction of highly resolved fields of view using polar coordinates. METHODS: System matrix is computed using a ray-tracing approach in cylindrical or spherical coordinates. By using polar symmetries inherent to the acquisition geometry, the system matrix size can be reduced by a factor corresponding to the number of acquired projections. Such an important decrease in size allows the system matrix to be precomputed, and loaded all at once into memory prior to reconstruction. By carefully ordering the field of view voxels and the sinogram data, reconstruction speed is also enhanced by a cache-oblivious computer implementation. The reconstruction algorithm is also compatible with the ordered-subsets acceleration method. A final polar-to-Cartesian transformation is applied to the reconstructed image in order to allow proper visualization. RESULTS: The ray-tracing and reconstruction algorithms were implemented in polar representation. Large 3D system matrices were calculated in cylindrical and spherical coordinates, and the performance assessed against Cartesian ray-tracers in terms of speed and memory requirements. Images of analytical phantoms were successfully reconstructed in both cylindrical and spherical coordinates. Fully 3D images of phantoms and small animals were acquired with a Gamma Medica Triumph X-O small animal CT scanner and reconstructed using the manufacturer's software and the proposed polar approach to demonstrate the accuracy and robustness of the later. The noise was found to be reduced while preserving the same level of spatial resolution, without noticeable polar artifacts. CONCLUSIONS: Under a reasonable set of assumptions, the memory size of the system matrix can be reduced by a factor corresponding to the number of projections. Using this strategy, iterative reconstruction from high resolution clinical and preclinical systems can be more easily performed using general-purpose personal computers.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.311
Teacher spread0.288 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207