A bus-based smart myoelectric electrode/amplifier
Bibliographic record
Abstract
The design of a bus-based smart myoelectric electrode/amplifier is described that is be used in conjunction with a multi-function prosthetic hand controller. This system incorporates several different control strategies including pattern classification of EMG to control a three axis hand (The UNB Hand) that can perform six basic grip patterns. The smart electrode/amplifier was designed to meet power consumption and size specifications of commercially available myoelectric amplifiers used for prosthetic control applications while providing a host of additional features. These features include a CAN bus communication protocol to alleviate wiring complexity, software programmable gain, distributed signal processing and electrode lift detection. In addition, this paper also compares the differences in requirements between a myoelectric electrode/amplifier used in a pattern classifier system to that used in a clinical setting. System testing and evaluation with normally limbed subjects and traumatic amputees are presented.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.002 | 0.001 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.011 | 0.005 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".