MétaCan
Menu
Back to cohort
Record W2035969537 · doi:10.1016/j.arthro.2014.01.013

A Cadaveric Analysis of Tunnel Position Created Using Flexible Versus Rigid Instrumentation in a Single‐Incision Distal Biceps Tendon Repair

2014· article· en· W2035969537 on OpenAlexaff
Khalid Alsheikh, Dominique Behrends, Adam Cota, Paul A. Martineau

Bibliographic record

VenueArthroscopy The Journal of Arthroscopic and Related Surgery · 2014
Typearticle
Languageen
FieldMedicine
TopicElbow and Forearm Trauma Treatment
Canadian institutionsMcGill University Health Centre
FundersNational Institutes of HealthSmith and Nephew
KeywordsReamerCadaveric spasmFixation (population genetics)Instrumentation (computer programming)CuretteAnterior cruciate ligamentBiomedical engineeringMedicineAnatomySurgeryMaterials science

Abstract

fetched live from OpenAlex

PURPOSE: This study was designed to determine whether the use of a flexible guide pin and reamer through an anterior single-incision approach would allow for a more anatomic insertion point on the radial tuberosity when compared with the traditional rigid instrumentation used for cortical button fixation. METHODS: Seven matched pairs of fresh-frozen cadaveric upper extremity specimens were used in this study. One specimen from each matched pair was randomly assigned to undergo a simulated repair using the standard instrumentation required for a cortical button fixation device, and the other specimens were assigned to undergo the same repair using a 42° anterior cruciate ligament femoral guide with a flexible guide pin and reamer. Each specimen from both groups was positioned with the elbow in 90° of flexion and the forearm maximally supinated during guide pin insertion. The proximal portion of the radius was then harvested from the specimen and scanned using micro-computed tomography (micro-CT). Tunnel position between the 2 techniques was compared with the center of the native tendon footprint. RESULTS: The mean percentage of the reamed entry hole within the tendon footprint was significantly less using rigid instrumentation (36.35%) compared with flexible instrumentation (67.29%) (P = .043). Furthermore, when flexible reamers were used (mean offset ratio, 0.17), the resultant tunnel was positioned in a significantly more central position within the radial shaft (i.e., the offset ratio was lower) compared with rigid reamers (mean offset ratio, 0.35) (P = .043). The entry hole was found to be significantly more posterior relative to the center of the anatomic footprint for the flexible reamer group (mean, 0.21 mm anterior) compared with the rigid reamer group (mean, 3.22 mm anterior) (P = .028). There was no difference in tunnel length between the 2 groups. CONCLUSIONS: The use of a flexible guide pin and reamer allows for a more anatomically positioned repair than does rigid instrumentation through a single-incision approach. CLINICAL RELEVANCE: This surgical technique allows for a more anatomic re-creation of the distal biceps tendon insertion while maintaining the benefits of a single limited anterior exposure.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.132
Threshold uncertainty score0.490

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.285
Teacher spread0.259 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueArthroscopy The Journal of Arthroscopic and Related SurgerySame topicElbow and Forearm Trauma TreatmentFrench-language works237,207