MétaCan
Menu
Back to cohort
Record W2036264858 · doi:10.1002/jmri.21867

Comparison of methods to assess quadriceps muscle volume using magnetic resonance imaging

2009· article· en· W2036264858 on OpenAlexaff
Antoine Nordez, Erwan Jolivet, I. Südhoff, Dominique Bonneau, Jacques A. de Guise, Wafa Skalli

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2009
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsÉcole de Technologie Supérieure
Fundersnot available
KeywordsMagnetic resonance imagingVolume (thermodynamics)Interpolation (computer graphics)ScannerSpline interpolationNuclear medicineMathematicsComputer scienceMedicineBiomedical engineeringPhysicsRadiologyMotion (physics)Computer visionArtificial intelligenceStatistics

Abstract

fetched live from OpenAlex

PURPOSE: To compare the precision of four methods to estimate the volume of quadriceps muscles using axial MRI. MATERIALS AND METHODS: Entire legs of 10 healthy young subjects were scanned using a 1.5 Tesla magnetic resonance imaging scanner and 4-mm-thick sections without any gaps. Quadriceps muscles were outlined on all of the slices to obtain the MRI reference standard measure of quadriceps muscle volume. This MRI reference standard was compared with the volume estimated using (i) the truncated cone formula, (ii) the Cavalieri method, (iii) a cubic spline interpolation of missing cross sectional areas, and, (iv) the deformation of a parametric specific object. For each method, 3 to 21 slices were used. RESULTS: The average volume error was significantly (P < 0.001) different in comparing the four methods (4.4%, 2.3%, 1.1%, and 1.2%, respectively). In addition, the number of slices required to reach a given volume error was significantly (P < 0.001) different across all methods (respectively, 12, 9, 5, and 7 slices required to reach a volume error of 1.1%). CONCLUSION: While methods based on interpolation and deformation of a parametric specific object have not been used in literature, these two methods are the most precise approaches to reach a given level of precision.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.879
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.344
Teacher spread0.309 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations81
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicMuscle activation and electromyography studiesFrench-language works237,207