Record W2036570100 · doi:10.1115/ijpgc2003-40036

Pickering B Nuclear Power Generating Station Condenser Performance Improvement

2003· article· en· W2036570100 on OpenAlexaffabout
Wayne Allen, David Anderson, Bert Mayer

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEnvironmental Science
TopicAquatic Invertebrate Ecology and Behavior
Canadian institutionsOntario Power Generation
Fundersnot available
KeywordsCondenser (optics)DreissenaMarine engineeringEngineeringWater coolingTube (container)Environmental scienceWaste managementMechanical engineeringGeologyPhysicsBivalvia

Abstract

fetched live from OpenAlex

The Ontario Power Generation (OPG) Pickering B Facility consists of four 540 MW nuclear generating units. Each unit is furnished with a once-through Condenser Cooling Water (CCW) System that uses Lake Ontario water. Zebra mussels (Dreissena polymorpha) are infesting the condenser cooling water intakes at Pickering. The mature mussels and their shells become entrained in the CCW, are deposited in the condenser inlet water boxes, and become lodged in the condenser tube sheets and within the tubes. As a result, the flow through the condenser is reduced, and the existing Condenser Tube Cleaning System (CTCS) performance is degraded. This reduces the Turbine-Generator generating capability that results in a loss of electric generation revenues for OPG, and increased maintenance costs to manually remove the zebra mussels from the condenser. OPG decided to install Debris Filters in the six 72-inch diameter inlets of each of the four Pickering B units to automatically remove the zebra mussels before they enter the condensers and discharge them back into the lake. The Debris Filters for Unit 8 were installed during a scheduled outage in the winter of 2001/2002. The Unit 5 installation was completed at the end of 2002 and the Unit 6 & 7 installations are scheduled for 2003. The installed equipment is performing as expected. The zebra mussels are intercepted by the Debris Filter, and are automatically discharged into the condenser bypass and returned to the lake. The CTCS system can again perform its intended function to prevent bio-fouling buildup inside the condenser tubes. As a result, generation capacity increased and maintenance expenditures decreased with a net result of increased revenues for OPG.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Other · Consensus signal: none
Teacher disagreement score0.778
Threshold uncertainty score0.441

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0200.004

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.200
Teacher spread0.192 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreOther

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2003
Admission routes2
Has abstractyes

Explore more

Same topicAquatic Invertebrate Ecology and Behavior→French-language works237,207→