MétaCan
Menu
Back to cohort
Record W2036888088 · doi:10.4103/0971-6203.62197

Dosimetry of interface region near closed air cavities for Co-60, 6 MV and 15 MV photon beams using Monte Carlo simulations

2010· article· en· W2036888088 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueJournal of Medical Physics · 2010
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsKingston General HospitalQueen's University
Fundersnot available
KeywordsTomotherapyDosimetryMonte Carlo methodPhotonRadiationIonization chamberRadiation therapyMaterials scienceDose profileBeam (structure)PhysicsOpticsNuclear medicineIonIonizationMedicineRadiology

Abstract

fetched live from OpenAlex

Underdosing of treatment targets can occur in radiation therapy due to electronic disequilibrium around air-tissue interfaces when tumors are situated near natural air cavities. These effects have been shown to increase with the beam energy and decrease with the field size. Intensity modulated radiation therapy (IMRT) and tomotherapy techniques employ combinations of multiple small radiation beamlets of varying intensities to deliver highly conformal radiation therapy. The use of small beamlets in these techniques may therefore result in underdosing of treatment target in the air-tissue interfaces region surrounding an air cavity. This work was undertaken to investigate dose reductions near the air-water interfaces of 1x1x1 and 3x3x3 cm(3) air cavities, typically encountered in the treatment of head and neck cancer utilizing radiation therapy techniques such as IMRT and tomotherapy using small fields of Co-60, 6 MV and 15 MV photons. Additional investigations were performed for larger photon field sizes encompassing the entire air-cavity, such as encountered in conventional three dimensional conformal radiation therapy (3DCRT) techniques. The EGSnrc/DOSXYZnrc Monte Carlo code was used to calculate the dose reductions (in water) in air-water interface region for single, parallel opposed and four field irradiations with 2x2 cm(2) (beamlet), 10x2 cm(2) (fan beam), 5x5 and 7x7 cm(2) field sizes. The magnitude of dose reduction in water near air-water interface increases with photon energy; decreases with distance from the interface as well as decreases as the number of beams are increased. No dose reductions were observed for large field sizes encompassing the air cavities. The results demonstrate that Co-60 beams may provide significantly smaller interface dose reductions than 6 MV and 15 MV irradiations for small field irradiations such as used in IMRT and tomotherapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.316
Threshold uncertainty score0.442

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.340
Teacher spread0.322 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it