MétaCan
Menu
Back to cohort
Record W2036926407 · doi:10.1115/1.2899572

Development of a Testing Methodology to Quantify Bone Load Transfer Patterns for Multiple Stemmed Implants in a Single Bone With an Application in the Distal Ulna

2008· article· en· W2036926407 on OpenAlexafffund
Rebecca L. Austman, Cheryl E. Quenneville, Brendon J. B. Beaton, Graham J.W. King, Karen Gordon, Cynthia E. Dunning

Bibliographic record

VenueJournal of Biomechanical Engineering · 2008
Typearticle
Languageen
FieldMedicine
TopicOrthopedic Surgery and Rehabilitation
Canadian institutionsUniversity of GuelphWestern University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsUlnaBiomedical engineeringComputer scienceEngineeringMedicineAnatomy

Abstract

fetched live from OpenAlex

Optimal parameters for many orthopaedic implants, such as stem length and material, are unknown. Geometry and mechanical properties of bone can vary greatly amongst cadaveric specimens, requiring a large number of specimens to test design variations. This study aimed to develop an experimental methodology to measure bone strains as a function of multiple implant stem designs in a single specimen, and evaluate its efficacy in the distal ulna. Eight fresh-frozen cadaveric ulnae were each instrumented with 12 uniaxial strain gauges on the medial and lateral surfaces of the bone. The proximal portion of each ulna was cemented in a custom-designed jig that allowed a medially directed force to be applied to the distal articular surface. An implant with a finely threaded stem was cemented into the canal by an experienced upper extremity orthopaedic surgeon. Six loads (5-30 N) were applied sequentially to the lateral surface of the prosthetic head using a materials testing machine. Testing was repeated after breaking the stem-cement bond, and after removing and reinserting the stem several times into the threaded cement mantle. Near the end of the testing period, the initial stem was reinserted and data were collected to determine if there was any change in bone properties or testing setup over time. Finally, a smooth stem was inserted for comparison to the threaded stem. Strain varied linearly with load (R(2)> or =0.99) for all testing scenarios. Bending strains were not affected by breaking the stem-cement bond (P=0.7), testing durations up to 18 h (P=0.7), nor the presence of threads when compared to a smooth stem (P>0.4). Furthermore, for all gauges, there was no interaction between the effect of the threads and level of applied load (P>0.1). This methodology should prove to be useful to compare stem designs of varying lengths and materials in the same bone, allowing for a direct comparison between implant designs for the ulna and other bones subjected primarily to bending loads. Furthermore, it will minimize the need for large numbers of specimens to test multiple implant designs. The ultimate goal of using this protocol is to optimize implant stem properties, such as length and material, with respect to load transfer.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.445
Threshold uncertainty score0.233

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.108
GPT teacher head0.310
Teacher spread0.202 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2008
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Biomechanical EngineeringSame topicOrthopedic Surgery and RehabilitationFrench-language works237,207