MétaCan
Menu
Back to cohort
Record W2037358480 · doi:10.2106/jbjs.j.01740

Landmarks for Rotational Alignment of the Humeral Component During Elbow Arthroplasty

2012· article· en· W2037358480 on OpenAlexaff
Marlis T. Sabo, George S. Athwal, Graham J.W. King

Bibliographic record

VenueJournal of Bone and Joint Surgery · 2012
Typearticle
Languageen
FieldMedicine
TopicElbow and Forearm Trauma Treatment
Canadian institutionsSt Joseph's Health Care
Fundersnot available
KeywordsElbowArthroplastyComponent (thermodynamics)OrthodonticsAnatomyMedicineComputer scienceSurgeryPhysics

Abstract

fetched live from OpenAlex

BACKGROUND: The reference points for rotational orientation of the humeral component during elbow arthroplasty typically are on the articular surface or the humeral epicondyles. With bone loss, these landmarks may be compromised. Our purpose was to assess whether the flat posterior humeral cortex proximal to the olecranon fossa is a reliable landmark with which to orient the humeral component during elbow arthroplasty. METHODS: Fifty cadaveric elbows (mean age [and standard deviation] at the time of death, 73 ± 12 years) underwent computed tomography (CT) scans. The flexion-extension axis (FEA) was determined by sphere-fitting the capitellar surface and circle-fitting the narrowest portion of the trochlea. The posterior humeral cortical line (PCL) was drawn on the flat posterior humeral cortex proximal to the olecranon fossa. The transepicondylar axis (TEA) was determined by a line between the most prominent points on the epicondyles. The angles between the PCL and FEA and the TEA and FEA were calculated and were compared by using two-tailed t tests. RESULTS: The PCL was externally rotated by a mean (and standard deviation) of 14.0° ± 4.2° (p < 0.001) relative to the FEA (males: 12.6° ± 3.6°, females: 16.4° ± 5.2°; p = 0.002). The TEA was externally rotated by a mean of 2.8° ± 3.5° (p < 0.001) relative to the FEA (males: 2.7° ± 3.4°, females: 2.6° ± 3.7°; p = 0.96). The intraobserver and interobserver reliability was >0.98 for the capitellar and trochlear centers, while the cumulative intraobserver and interobserver reliability was 0.8 and 0.5 for the FEA-PCL angle and 0.4 and 0.3 for the FEA-TEA angle. CONCLUSIONS: The posterior humeral cortex is a reproducible landmark that is externally rotated with respect to the flexion-extension axis of the distal part of the humerus. The surgeon must be aware of the need for an internal rotation correction factor and consider the influence of the patient's sex on this correction when using the posterior humeral cortex as a landmark to avoid humeral component malrotation. CLINICAL RELEVANCE: While the PCL is better than the TEA as a reference point, neither is able to accurately identify the FEA because of considerable normal variation. Future studies are needed to evaluate the effectiveness of computer-assisted techniques or a preoperative CT scan of the contralateral, unaffected elbow in identifying rotational landmarks for the elbow undergoing arthroplasty.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.246
Teacher spread0.216 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations53
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Bone and Joint SurgerySame topicElbow and Forearm Trauma TreatmentFrench-language works237,207