Selected Volatile Organic Compounds in Residential Air in the City of Ottawa, Canada
Bibliographic record
Abstract
Airborne levels of selected volatile organic chemicals (VOCs) that are priorities for exposure assessment under the Canadian Environmental Protection Act (CEPA) 1999 were measured in both indoor air and outdoor air of 75 residential houses, in the city of Ottawa, Canada, during the winter of 2002/2003. The houses were randomly selected using Ottawa 2001 population census data. VOCs were collected on adsorbent tubes and measured by thermal desorption GC/MS. Among 37 chemicals monitored, 17 were detected with a frequency greater than 80% in indoor air; 9 were between 30% and 80%; 7 were between 1% and 30%; and 4 were not detected. Concentrations of VOCs in both indoor and outdoor air are presented. Virtually all of the target VOCs were detected more frequently and were present at significantly higher levels, in indoor air than in outdoor air. As an indication of the contribution of indoor levels of these chemicals, ratios of the concentration found in indoor air to outdoor air (I/O) and the indoor source strength expressed in estimated emission rate per house are also presented. Compared with earlier published studies including a 1991/1992 Canadian national survey of VOCs in residential air, levels of target analytes in indoor air in this study were lower for a number of chemicals, indicating a possible trend toward decreased inhalation exposure to these chemicals in residential environments. This study has yielded up-to-date information on levels of a variety of priority airborne chemicals in residential air, which is being used to estimate current exposure to these substances as input to health risk assessments and risk management actions under CEPA 1999.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.002 |
| Science and technology studies | 0.000 | 0.002 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".