MétaCan
Menu
Back to cohort
Record W2038017040 · doi:10.1002/cjce.20542

Comparison of the impact of flow pulsations on the performance of various liquid–gas injectors in a gas–solid fluidised bed

2011· article· en· W2038017040 on OpenAlexaffvenueabout
Rana Sabouni, Franco Berruti, Cédric Briens

Bibliographic record

VenueThe Canadian Journal of Chemical Engineering · 2011
Typearticle
Languageen
FieldEngineering
TopicGranular flow and fluidized beds
Canadian institutionsWestern University
Fundersnot available
KeywordsNozzleInjectorBody orificeSpray characteristicsVolumetric flow rateMaterials scienceSpray nozzleMechanicsFlow (mathematics)Nuclear engineeringMechanical engineeringEngineeringPhysics

Abstract

fetched live from OpenAlex

Abstract This article shows that spray nozzles pulsations can greatly improve the distribution of the sprayed liquid on fluidised bed particles, as characterised by a Nozzle Performance Index (NPI). Appropriate pulsations increased the NPI by nearly 100% under several operating conditions. This article compares four pulsating, gas atomised nozzles under various operating conditions. The performance of each nozzle was evaluated by measuring the electric conductance of a bed of silica sand particles fluidised by air, subsequent to liquid injection. Three sets of experiments were conducted to investigate the effect of operating conditions on the performance of the four gas atomised nozzles. The first set determined the effect of the liquid flowrate, the second set measured the effect of a restriction orifice on the atomisation gas line and the third set studied the effect of the atomisation air to liquid ratio. Artificial nozzle spray pulsations were found to have similar beneficial effects with the different types of gas‐atomised nozzles. © 2011 Canadian Society for Chemical Engineering

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.218
Teacher spread0.203 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2011
Admission routes3
Has abstractyes

Explore more

Same venueThe Canadian Journal of Chemical EngineeringSame topicGranular flow and fluidized bedsFrench-language works237,207