MétaCan
Menu
Back to cohort

Automatic Sensor Algorithms Expedite Pacemaker Follow‐ups

2003· article· en· W2038476729 on OpenAlexaff
Demo Klonis, Xiaozheng Zhang, Umesh Patel, Sajad Gulamhusein, Jagdish K. Patel, HANDRE HURWIT, Dorothy Banish, Dave Marco

Bibliographic record

VenuePacing and Clinical Electrophysiology · 2003
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsGrey Nuns Community Hospital
Fundersnot available
KeywordsMedicineAlgorithmInternal medicineComputer science

Abstract

fetched live from OpenAlex

OBJECTIVE: Automatic algorithms can be used to optimize settings and reduce the duration of pacemaker (PM) clinical follow-up. METHODS: This study prospectively evaluated 87 patients (74.2 +/- 10.7 years old, 52% men) who received PM with the Autoslope algorithm. Patients randomized to the manual group (group M, n = 43) performed a walk test and used sensor-indicated rate histograms to adjust the sensor, while in the automatic group (group A, n = 44) the sensor was automatically adjusted by the Autoslope. The patients were followed for 6 months. Follow-up time required for device interrogation and optimal sensor set-up, and the number of sensor parameters reprogramming were recorded. Changes in the patients' activity level were also evaluated. RESULTS: Group A required significantly less follow-up time than group M (9.4 +/- 5.7 min vs 13.5 +/- 8.5 min, P = 0.0002). The average number of sensor parameters reprogrammed during visits was significantly lower in group A than M (0.6 +/- 0.9 vs 0.9 +/- 1.3, P = 0.048). Threshold was adjusted 34.4% of the time in the sensor evaluations in group M versus 12.9% in group A (P = 0.0004). Although more patients in group A reported being more active, the changes in patients' activity level did not lead to increasing sensor setup time or number of parameter reprogramming in either group. CONCLUSIONS: Auto sensor adjustment required less time during routine PM clinical follow-up by reducing steps needed for manual sensor threshold adjustment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.006
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.354
Teacher spread0.320 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2003
Admission routes1
Has abstractyes

Explore more

Same venuePacing and Clinical ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207