MétaCan
Menu
Back to cohort
Record W2038879481 · doi:10.1039/c4an00765d

Fabrication and laser patterning of polystyrene optical oxygen sensor films for lab-on-a-chip applications

2014· article· en· W2038879481 on OpenAlexafffund
Samantha M. Grist, Nominerdene Oyunerdene, Jonas Flueckiger, J. Kim, P.C. Wong, Lukas Chrostowski, Karen C. Cheung

Bibliographic record

VenueThe Analyst · 2014
Typearticle
Languageen
FieldChemical Engineering
TopicAnalytical Chemistry and Sensors
Canadian institutionsUniversity of British Columbia
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchCMC Microsystems
KeywordsPolystyreneFabricationMaterials scienceNanotechnologyLaserLab-on-a-chipChipOptoelectronicsOxygen sensorOxygenChemistryOpticsPolymerComputer scienceMicrofluidicsComposite materialOrganic chemistryPhysicsTelecommunications

Abstract

fetched live from OpenAlex

We present a novel and simple method for patterning oxygen-sensitive polystyrene thin films and demonstrate its potential for integration with microfluidic lab-on-a-chip devices. Optical oxygen sensing films composed of polystyrene with an embedded luminescent oxygen-sensitive dye present a convenient option for the measurement of oxygen levels in microfluidic and lab-on-a-chip devices; however, patterning and integrating the films with poly(dimethylsiloxane) (PDMS) microfluidic devices has proven difficult due to a residue after dry etch patterning that inhibits subsequent PDMS bonding. Our new method uses mask-less laser ablation by a commercial laser ablation system to define the outline of the structures and subsequent bulk film removal by aqueous lift-off. Because the bulk film is peeled or lifted off of the substrate rather than etched, the process is compatible with standard PDMS plasma bonding. We used ToF-SIMS analysis to investigate how laser ablation facilitates this fabrication process as well as why dry etching polystyrene inhibits PDMS plasma bonding. The results of this analysis showed evidence of chemical species formed during the laser ablation and dry etching processes that can produce these effects. Our new method's mask-less nature, simplicity, speed, and compatibility with PDMS bonding make it ideally suited for single-use lab-on-a-chip applications. To demonstrate the method's compatibility with PDMS microfluidics, we also present a demonstration of the sensors' integration into a microfluidic oxygen gradient generator device.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.238
Teacher spread0.225 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueThe AnalystSame topicAnalytical Chemistry and SensorsFrench-language works237,207