MétaCan
Menu
Back to cohort
Record W2039039193 · doi:10.1002/ccd.20795

Percutaneous closure of prosthetic paravalvular leaks: Case series and review

2006· review· en· W2039039193 on OpenAlexaff
Gordon E. Pate, Abdul Al Zubaidi, Mann Chandavimol, Christopher Thompson, Bradley Munt, John G. Webb

Bibliographic record

VenueCatheterization and Cardiovascular Interventions · 2006
Typereview
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsUniversity of British ColumbiaSt. Paul's Hospital
Fundersnot available
KeywordsMedicinePercutaneousSurgeryDuctus arteriosusLeakAsymptomaticValve replacementCardiac catheterizationComplicationRadiologyStenosis

Abstract

fetched live from OpenAlex

BACKGROUND: Paravalvular leaks (PVLs) are a well-recognized complication of prosthetic valve replacement. Most are asymptomatic and benign, but some may cause symptoms due to a large regurgitant volume or hemolysis. Medical therapy is palliative, while reoperation carries significant morbidity and mortality. Percutaneous transcatheter closure techniques, now routinely applied in the management of pathological cardiac and vascular communications, may be adaptable to PVL closure, potentially offer symptomatic relief. METHODS: We reviewed our experience with attempted percutaneous closure of PVLs, using data from medical and procedural records. RESULTS: Between 2001 and 2004, 14 procedures were performed in 10 patients, all under general anesthesia, with transesophageal and radiographic guidance. Mitral (9) and aortic (1) valve replacements were involved, both mechanical and bioprosthetic. A variety of devices were used, including atrial septal occluders, patent ductus arteriosus occluders, and coils (all of label use). Six had a single procedure, which was technically successful in four: in two, the PVL could not be crossed. Four underwent a second procedure, which was technically successful in three; in one the previously deployed device was dislodged necessitating urgent, but ultimately uneventful, surgical removal and leak repair. One patient had transient severe hemolysis, which resolved after 1 week. At 1-year follow-up (9/10 pts) three had died, five had sustained symptomatic improvement while 1 patient with a residual leak still required regular blood transfusions. CONCLUSIONS: Percutaneous closure of PVLs is time-consuming but feasible in selected patients, with a reasonable degree of technical and clinical success. A second procedure may be necessary and a variety of complications can occur.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: Case report
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.006
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0060.005
Science and technology studies0.0010.001
Scholarly communication0.0010.002
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0020.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.369
Teacher spread0.330 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designCase report
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations189
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueCatheterization and Cardiovascular InterventionsSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207