MétaCan
Menu
Back to cohort
Record W2039592178 · doi:10.1118/1.3326947

Effect of repeated x‐ray exposure on the resolution of amorphous selenium based x‐ray imagers

2010· article· en· W2039592178 on OpenAlexafffund
M. Z. Kabir, Laila Chowdhury, Giovanni DeCrescenzo, O. Tousignant, Safa Kasap, J. A. Rowlands

Bibliographic record

VenueMedical Physics · 2010
Typearticle
Languageen
FieldMedicine
TopicDigital Radiography and Breast Imaging
Canadian institutionsThunder Bay Regional Research InstituteHealth Sciences CentreUniversity of SaskatchewanCégep de Saint-LaurentUniversity of TorontoSunnybrook Health Science CentreLakehead UniversityConcordia University
FundersNational Institute of Biomedical Imaging and BioengineeringNatural Sciences and Engineering Research Council of CanadaNational Institutes of Health
KeywordsOpticsSensitivity (control systems)Optical transfer functionPhysicsElectric fieldX-rayPhoton energyX-ray detectorMaterials scienceComputational physicsPhotonDetector

Abstract

fetched live from OpenAlex

PURPOSE: A numerical model and the experimental methods to study the x-ray exposure dependent change in the modulation transfer function (MTF) of amorphous selenium (a-Se) based active matrix flat panel imagers (AMFPIs) are described. The physical mechanisms responsible for the x-ray exposure dependent change in MTF are also investigated. METHODS: A numerical model for describing the x-ray exposure dependent MTF of a-Se based AMFPIs has been developed. The x-ray sensitivity and MTF of an a-Se AMFPI have been measured as a function of exposure. The instantaneous electric field and free and trapped carrier distributions in the photoconductor layer are obtained by numerically solving the Poisson's equation, continuity equations, and trapping rate equations using the backward Euler finite difference method. From the trapped carrier distributions, a method for calculating the MTF due to incomplete charge collection is proposed. RESULTS: The model developed in this work and the experimental data show a reasonably good agreement. The model is able to simultaneously predict the dependence of the sensitivity and MTF on accumulated exposure at different applied fields and bias polarities, with the same charge transport parameters that are typical of the particular a-Se photoconductive layer that is used in these AMFPIs. Under negative bias, the MTF actually improves with the accumulated x-ray exposure while the sensitivity decreases. The MTF enhancement with exposure decreases with increasing applied field. CONCLUSIONS: The most prevalent processes that control the MTF under negative bias are the recombination of drifting holes with previously trapped electrons (electrons remain in deep traps due to their long release times compared with the time scale of the experiments) and the deep trapping of drifting holes and electrons.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.237
Teacher spread0.232 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations28
Published2010
Admission routes2
Has abstractyes

Explore more