MétaCan
Menu
Back to cohort
Record W2039832428 · doi:10.1259/bjr/32191494

A comparative evaluation of two head and neck immobilization devices using electronic portal imaging

2006· article· en· W2039832428 on OpenAlexaff
Katia Donato, Konrad Leszczyński, Kathryn H. Fleming

Bibliographic record

VenueBritish Journal of Radiology · 2006
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsSudbury Regional Hospital
Fundersnot available
KeywordsHead and neckMedicineHead (geology)RadiologyNuclear medicineMedical physicsSurgeryGeology

Abstract

fetched live from OpenAlex

A study was performed to compare the positioning reproducibility and the cost efficiency for two head and neck immobilization devices: the Uvex (Uvex Safety, Smithfield, USA) plastic mask system and the Finesse Frame with Ultraplast System (PLANET Medical, Svendborg, Denmark). 20 patients treated with 3D conformal radiation therapy for head and neck cancers were randomly selected (10 for each of the two different immobilization systems) and electronic portal images acquired during their course of treatment were saved and used in this study. The anatomical landmark coordinates and their shifts in the anteroposterior (AP) and craniocaudal (CC) directions with respect to the digitized simulator films for lateral fields were analysed using an in-house developed portal image registration system. Statistically, no evidence was found to indicate that the systematic components of the displacement for the Uvex system and the Finesse Frame with Ultraplast System were different from each other or from zero. The random component of displacement was slightly smaller in the AP direction for the Uvex than the Ultraplast system (sigma = 1.9 mm and 2.9 mm, respectively, p = 0.007), but larger in the CC direction (sigma = 3.8 mm and 2.2 mm, respectively, p<10(-9)). Production time and required materials for a radiation therapy department were also quantified to assess costs for each system. The overall costs per patient were estimated at 141.50 dollars (CAD) and 82.10 dollars for the Uvex and Ultraplast systems, respectively. The Finesse Frame with Ultraplast System of immobilization for head and neck cancer treatment provides a field placement reproducibility that is equal to, or greater than, that of the Uvex plastic mask immobilization system and, while it requires more expensive materials, the workload and consequently overall cost is greatly reduced.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.320
Threshold uncertainty score0.335

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.338
Teacher spread0.322 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueBritish Journal of RadiologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207