MétaCan
Menu
Back to cohort
Record W2041296185 · doi:10.1001/archotol.128.1.44

Development and Validation of the Neck Dissection Impairment Index

2002· article· en· W2041296185 on OpenAlexaff
Rodney J. Taylor, Judith C. Chepeha, Theodoros N. Teknos, Carol R. Bradford, Pramod Kumar Sharma, Jeffrey E. Terrell, Norman D. Hogikyan, Gregory T. Wolf, Douglas B. Chepeha

Bibliographic record

VenueArchives of Otolaryngology - Head and Neck Surgery · 2002
Typearticle
Languageen
FieldMedicine
TopicNerve Injury and Rehabilitation
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsNeck dissectionCronbach's alphaMedicineQuality of life (healthcare)Physical therapyConvalescenceSurgeryCancerPsychometricsInternal medicineClinical psychology

Abstract

fetched live from OpenAlex

OBJECTIVES: To validate a health-related quality-of-life (QOL) instrument for patients following neck dissection and to identify the factors that affect QOL following neck dissection. DESIGN: Cross-sectional validation study. SETTING: The outpatient clinic of a tertiary care cancer center. PATIENTS: Convenience sample of 54 patients previously treated for head and neck cancer who underwent a selective neck dissection or modified radical neck dissection (64 total neck dissections). Patients had a minimum postoperative convalescence of 11 months. Thirty-two underwent accessory nerve-sparing modified radical neck dissection, and 32 underwent selective neck dissection. MAIN OUTCOME MEASURE: A 10-item, self-report instrument, the Neck Dissection Impairment Index (NDII), was developed and validated. Reliability was evaluated with test-retest correlation and internal consistency using the Cronbach alpha coefficient. Convergent validity was assessed using the 36-Item Short-Form Health Survey (SF-36) and the Constant Shoulder Scale, a shoulder function test. Multiple variable regression was used to determine variables that most affected QOL following neck dissection RESULTS: The 10-item NDII test-retest correlation was 0.91 (P<.001) with an internal consistency Cronbach alpha coefficient of.95. The NDII correlated with the Constant Shoulder Scale (r = 0.85, P<.001) and with the SF-36 physical functioning (r = 0.50, P<.001) and role-physical functioning (r = 0.60, P<.001) domains. Using multiple variable regression, the variables that contributed most to QOL score were patient's age and weight, radiation treatment, and neck dissection type. CONCLUSIONS: The NDII is a valid, reliable instrument for assessing neck dissection impairment. Patient's age, weight, radiation treatment, and neck dissection type were important factors that affect QOL following neck dissection.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.011
metaresearch head score (Gemma)0.019
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.011
Threshold uncertainty score0.057

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0110.019
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.255
Teacher spread0.236 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations158
Published2002
Admission routes1
Has abstractyes

Explore more

Same venueArchives of Otolaryngology - Head and Neck SurgerySame topicNerve Injury and RehabilitationFrench-language works237,207