MétaCan
Menu
Back to cohort
Record W2041359790 · doi:10.1177/0954411911410642

The biomechanics of plate repair of periprosthetic femur fractures near the tip of a total hip implant: the effect of cable-screw position

2011· article· en· W2041359790 on OpenAlexafffund
A Dubov, S Y R Kim, S Shah, Emil H. Schemitsch, Radovan Zdero, Habiba Bougherara

Bibliographic record

VenueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · 2011
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsUniversity of TorontoToronto Metropolitan UniversitySt. Michael's Hospital
FundersNatural Sciences and Engineering Research Council of CanadaStryker
KeywordsPeriprostheticFemurImplantMaterials scienceBiomechanicsOrthodonticsTotal hip arthroplastyvon Mises yield criterionStiffnessBiomedical engineeringArthroplastyStructural engineeringFinite element methodSurgeryComposite materialMedicineAnatomyEngineering

Abstract

fetched live from OpenAlex

Optimal surgical positioning of cable-screw pairs in repairing periprosthetic femur fractures near the tip of a total hip implant still remains unclear. No studies in the literature to date have developed a fully three-dimensional finite element (FE) model that has been validated experimentally to assess these injury patterns. The aim of the present study was to evaluate the biomechanical performance of three different implant-bone constructs for the fixation of periprosthetic femoral shaft fractures following total hip arthroplasty. Experimentally, three bone-plate repair configurations were applied to the periprosthetic synthetic femur fractured with a 5 mm gap near the tip of a total hip implant. Constructs A, B, and C, respectively, had successively larger distances between the most proximal and the most distal cable-screw pairs used to affix the plate. Specimens were oriented in 15 degrees adduction, subjected to 1000 N of axial force to simulate the single-legged stance phase of walking, and instrumented with strain gauges. Computationally, a linearly elastic and isotropic three-dimensional FE model was developed to mimic the experimental setup. Results showed excellent agreement between experimental versus FE analysis strains, yielding a Pearson linearity coefficient, R2, of 0.90 and a slope for the line of best data fit of 0.96. FE axial stiffnesses were 601 N/mm (Construct A), 849 N/mm (Construct B), and 1359 N/mm (Construct C). FE surface stress maps for cortical bone showed maximum von Mises values of 74 MPa (Construct A), 102 MPa (Construct B), and 57 MPa (Construct C). FE stress maps for the metallic components showed minimum von Mises values for Construct C, namely screw (716MPa), cable (445MPa), plate (548MPa), and hip implant (154MPa). In the case of good bone stock, as modelled by the present synthetic femur model, optimal fixation can be achieved with Construct C.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.233
Teacher spread0.223 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations67
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineSame topicOrthopaedic implants and arthroplastyFrench-language works237,207