MétaCan
Menu
Back to cohort
Record W2041702794 · doi:10.1186/s40679-014-0001-3

Outrun radiation damage with electrons?

2015· article· en· W2041702794 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueAdvanced Structural and Chemical Imaging · 2015
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicAdvanced Electron Microscopy Techniques and Applications
Canadian institutionsUniversity of Alberta
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsElectronElectron microscopeCoherence (philosophical gambling strategy)Electron diffractionAtomic physicsTransmission electron microscopyRadiation damageResolution (logic)Nanocrystalline materialRadiationOpticsCathode rayMaterials sciencePhysicsNanotechnologyDiffractionNuclear physicsComputer scienceQuantum mechanics

Abstract

fetched live from OpenAlex

Abstract The diffract-before-destroy method, using 50- to 100-fs x-ray pulses from a free-electron laser, was designed to determine the three-dimensional structure of biological macromolecules in close to their natural state. Here we explore the possibility of using short electron pulses for the same purpose and the related question of whether radiation damage can be outrun with electrons. Major problems include Coulomb repulsion within the incident beam and the need for high lateral coherence, difficulties that are discussed in terms of existing and future electron sources. Using longer pulses of electrons appears to make the attainment of near-atomic resolution more feasible, at least for nanocrystalline particles, whereas obtaining this information from single-molecule particles in an aqueous environment seems a more distant goal. We also consider the possibility of serial crystallography using a liquid jet injector with a continuous electron beam in a transmission electron microscope (TEM).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.023
Threshold uncertainty score0.406

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.282
Teacher spread0.278 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it