Automated Measurement of Blood Pressure in Routine Clinical Practice
Bibliographic record
Abstract
In recent years, automated devices have been developed to record blood pressure (BP) accurately in the home and during usual daily activities. Clinical outcome studies have clearly shown home BP and 24-hour ambulatory BP to be significantly better predictors of future cardiovascular events compared with BP recorded in the office setting using mercury sphygmomanometry. It is also now possible to measure office BP with the patient resting quietly alone in the examining room using an automated device. Studies in routine clinical practice using this approach have demonstrated that automated office BP can eliminate most of the white coat effect seen with manual BP measurement. The automated office BP also correlates significantly better than does the routine office BP with the 24-hour ambulatory BP, the gold standard for predicting risk of future cardiovascular events. Sufficient evidence now exists to consider incorporating automated office BP into an algorithm for diagnosing hypertension.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.026 | 0.033 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.013 | 0.003 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.002 | 0.004 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; both teacher heads agree on what is shown here.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".